Disassembly Procedures
!
5. Remove 6 screws on Front Panel top and bottom.
6. Lift front Panel from hanger hooks.
7. Disconnect Door Latch wire connector.
©2004 Maytag Services
WARNING
16023430 Rev. 0
To avoid risk of electrical shock, personal injury or
death; disconnect power to unit before servicing.
8. Remove 2 screws retaining Door Latch to Front
Panel.
Motor and Belt Removal
1. Disconnect power supply to unit.
2. Remove 3 screws retaining Back Cover.
3. Remove belt by pulling belt while rotating pulley
causing belt to derail from motor.
4. Remove Motor wiring connector and ground wires.
21