8.6

TX Power Test

Use this test on a unit having bad transmission (TX) or intermittent service failures. (This is a
transmitter test only.)
Set up the R-2660 for Spectrum
Analyzer display, and
connect the unit to the
RF IN/OUT connector.
Connect the regulated battery
eliminator to the unit to be tested.
Remove the antenna from the unit.
Set the power supply between 5.0
and 12.0 Vdc.
Power up unit. Enter Test Mode
(see Entering Test Mode).
Press Menu, Edit,
Ok.
Scroll down until 800 POW 2 is
highlighted.
Press Ok, Back, Menu,
Start.
Press TX ON to start
transmitting.
68P80401P05
FIELD LEVEL TEST MODES AND PROCEDURES: TX Power Test
Notes:
1.
Place the unit into Test Mode for this test.
2.
Unit will transmit at greater than 24 dBm.
3.
In the United States, the Main board can only be replaced and
programmed at the factory or iDEN Radio Support Center.
Watch for a signal on the
R-2660. (Make sure the R-2660
is set for the proper frequency:
813.5125MHz.)
Pass
Press STOP.
Press Exit on the unit to exit this
mode, or press Menu, Edit, right
Scroll key to continue on to BER
test.
Replace the
Fail
Main board, and
repeat the test.
Continue with the
BER test.