Air-conditioner Control System
Centralized Controller
Model: AG-150A
Before installing the controller, please read this Installation Manual carefully to ensure
proper operation. Retain this manual for future reference.
Installation Manual
Contents
1. Safety Precautions ..................................................1
2. Parts List .................................................................2
3. External Dimensions ...............................................3
4. Product Features.....................................................4
1. Specification......................................................4
2. Parts names and functions ...............................4
5. System Diagram......................................................6
equipments) ..................................................6
units) .............................................................8
6. Installation .............................................................10
1. Field-supplied Parts ........................................10
2. Installation.......................................................10
7. Wiring ....................................................................21
expansion controller....................................21
expansion controller....................................22
8. Initial Setting..........................................................23
9. Test Run................................................................24
10. System Configuration Example.............................25
expansion controller....................................25
3. To control a Mr. slim .......................................25
4. To control a K control model ...........................25
11. External input/output usage ..................................26
1. External signal input function ..........................26
2. External signal output function........................27
3. LAN connection function .................................28
12. Optional Accessories ............................................29

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi AG-150A

  • Page 1: Table Of Contents

    4. Product Features.............4 1. Specification............4 2. Parts names and functions .......4 5. System Diagram............6 1. Standard configuration (using the AG-150A to control a system with 50 or fewer units of equipments) ..........6 2. System with connection to an expansion controller (system with 50 or more units) .............8...
  • Page 2: Safety Precautions

    Consult an authorized agency for the proper disposal Use a security device such as a VPN router when of the unit. connecting the AG-150A to the Internet to prevent The unit contains mercury, which is harmful to the environment. unauthorized access.
  • Page 3: Parts List

    Up to three expansion controllers can be connected to a system, each of which can control up to 50 units of equipments. To control 50 or more units of equipments, use AG-150A software version 2.10 or later. - 2 -...
  • Page 4: External Dimensions

    3 External Dimensions Unit: mm (in) 25.6 ( - / 44.7 ( - 300 ( - 272 ( 0- Back View 272 (10- 250 (9- A type installation plate B type installation plate Unit: mm (in) 300 (11- 290.8 (11- 278 (10- 273 (10- 250 (9-...
  • Page 5: Product Features

    Up to 50 indoor units and general equipment can be monitored and operated from an AG-150A unit. By connecting three PAC-YG50ECA expansion controllers (sold separately), a maximum of 150 units of equipments can be controlled.
  • Page 6 Left view USB storage device Connects to a USB storage device to copy data from the AG-150A Back View Unused Unused Connects to other units of equipments over the LAN via a HUB. Connects to the power cable when the mounting attachment A type Connects to PAC-YG10HA (PAC-YG85KTB;...
  • Page 7: System Diagram

    5 System Diagram 1. Standard configuration (using the AG-150A to control a system with 50 or fewer units of equipments) POWER (24VDC) Indoor unit Centralized controller Power supply unit (optional) Local remote controller Model:AG-150A Model: PAC-SC51KUA M-NET transmission line K transmission line...
  • Page 8 5 The remote controller address does not need to be included in the K-control unit group settings. NOTE * Some types of units cannot be controlled from the AG-150A controller. 1-1. M-NET wiring configuration (1) Types and maximum allowable length of M-NET transmission cables...
  • Page 9: System With Connection To An Expansion Controller (System With 50 Or More Units)

    * The DB No. of PAC-YG50ECA is found on the package box and the controller itself in the [DB No. : **] format. Only the expansion controllers with the same DB No. as the AG-150A can be connected to the AG-150A. Be sure to check the DB No.
  • Page 10 * Up to three PAC-YG50ECA controllers can be connected to each AG-150A unit. * Main system controllers (e.g., AG-150A) cannot be connected to an M-NET system that is controlled by an expansion controller. * Main and sub system controllers (M-NET) AG-150A is for exclusive use as a main SC.
  • Page 11: Installation

    2. Installation The controller can be installed by following one of the methods below: By embedding the centralized controller in the wall. Method of using two plates included with AG-150A. AG-150A Wall By embedding the centralized controller in the wall and Electric box mounting it to an electric box.
  • Page 12 Power supply unit (PAC-SC51KUA; sold separately) Attach the AG-150A to the control board. Wall AG-150A Power supply unit (PAC-SC51KUA; sold Control board separately) 2-1. Embedding the centralized controller in the wall.
  • Page 13 * If the screw provided for the installation plate, cannot be used because of the wall thickness, use an M4 flathead screw that matches the wall thickness. 5 Remove the AG-150A surface cover. Insert a flat-tip screwdriver in the holes indicated...
  • Page 14 M4 roundhead screw (supplied) 8 Replace the AG-150A surface cover. 2-2. Wall-Embedded installation with an Electric box (PAC-YG83UTB; sold separately) 1 Ensure there is enough space to install the controller as shown below. Wall space (see diagram below) and 60 mm (2- in) of clearance behind the wall are required to mount an Electric box.
  • Page 15 Wall 7 Remove the AG-150A surface cover. 8 Connect the M-NET transmission cable (centralized control cable that is connected to TB2 of the power supply unit (PAC-SC51KUA)) to M-NET transmission cable terminal A, B (both non polarity) and S.
  • Page 16 9 Attach the controller to the A type installation plate with the roundhead screws (supplied). M4 rounded screw (supplied) Wall 0 Replace the AG-150A surface cover. 2-3. Wall-mounting the centralized controller with the mounting attachment B type (PAC-YG81TB; sold separately) 1 Ensure there is enough space to install the controller as shown in the figure at right.
  • Page 17 5 Install the mounting attachment B type (PAC-YG81TB; sold separately) on the wall with the six screws (field-supplied; Wall use screws that are suitable for the type of wall the AG-150A is installed on). Prior to installation, check that the wall is strong enough to Screws support the weight of the controller.
  • Page 18 2 Install the mounting attachment A type (PAC-YG85KTB; sold separately) on the wall with the six screws (field-supplied; use screws that are suitable for the type of wall the AG-150A is installed on). Prior to installation, check that the wall is strong enough to Knockout hole support the weight of the controller.
  • Page 19 (PAC-YG85KTB) with the four M4 rounded screws (supplied with PAC-YG85KTB). M4 roundhead screw (supplied with PAC- YG85KTB). b Replace the AG-150A surface cover. c Attach the power supply unit cover with the two screws. (Supplied with PAC-YG85KTB) Screws (supplied with PAC-YG85KTB) - 18 -...
  • Page 20 2-5. Installing the centralized controller on the control board 1 Make sure that there is an adequate amount of space to Unit: mm (in) install the controller as shown in the figure on the right. 30 (1- 300 (11- Control board NOTES * When installing two or more controllers side-by-side and horizontally ensure that there is at least 130 mm (5- in) or more...
  • Page 21 (supplied) M4 flathead screw (supplied) Control board 8 Remove the AG-150A surface cover. 9 Install the AG-150A on the A type installation plate with the M4 roundhead screws (supplied). M4 roundhead screw (supplied) 0 Replace the AG-150A surface cover.
  • Page 22: Wiring

    * Use a ring terminal to connect to the terminal block NOTES Connecting the M-NET transmission line to the AG-150A. * Connect the M-NET transmission to the centralized controller system side, and supply power to the M-NET from PAC- SC51KUA.
  • Page 23: System With Connection To A Pac-Yg50Eca Expansion Controller

    Connecting the PAC-YG50ECA expansion controller (sold separately) * Supply 24 VDC power from PAC-SC51KUA to the AG-150A when using PAC-YG50ECA. * M-NET transmission line does not need to be connected to the AG-150A or PAC-SC51KUA. Signal communication from the AG-150A is performed entirely over the LAN.
  • Page 24: Initial Setting

    8 Initial Setting NOTES * Choose from two initial setting methods: 1) Making the settings via AG-150A, 2) Making the setting via the LAN using the Initial Setting Web. • This manual provides the instructions on making the initial settings from AG-150A.
  • Page 25: Test Run

    5 After confirming that all units are operating properly, stop the units either from AG-150A or from the remote controllers. * Please refer to the Installation Manual that came with the indoor unit for further details on the test run method.
  • Page 26: System Configuration Example

    (Sub system controller) Power supply unit for transmission line (Model name: PAC-SC51KUA) • Make the initial settings (e.g., group settings and interlock settings) from the AG-150A, which is a main system controller, or from the Initial Settings Web. • Designate a single system controller in a given system from which operation prohibition signal can be sent.
  • Page 27: External Input/Output Usage

    * When using a PAC-YG50ECA expansion controller, connect the external input/output adapter to the external input terminal on the expansion controller, not to the AG-150A. * Make necessary settings for each expansion controller from the AG-150A on the Network Settings window (external input settings).
  • Page 28: External Signal Output Function

    NOTE * When using a PAC-YG50ECA expansion controller, connect the external input/output adapter to the external input terminal on the expansion controller, not to the AG-150A. (1) External output When one or more air conditioners are operating, the “ON” signal will be output, if a malfunction occurs in one or more air conditioners, the “Malfunction”...
  • Page 29: Lan Connection Function

    When using the LAN connection function, insert the LAN cable to the LAN connector of the controller. * Connect the LAN cable from the AG-150A to other equipments via a HUB. * The maximum LAN cable distance from the AG-150A is 100 m (328 ft).
  • Page 30: Optional Accessories

    50 units. Enables the connection of up to 150 indoor and Expansion controller PAC-YG50ECA (Up to three expansion LOSSNAY units to an AG-150A. controllers can be connected to a system.) Electric box PAC-YG83UTB Use for wall-embed installations...
  • Page 32 Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BLDG. , 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Authorized representative in EU: MITSUBISHI ELECTRIC EUROPE B.V. HARMAN HOUSE, 1 GEORGE STREET, UXBRIDGE, MIDDLESEX UB8 1QQ, U.K. WT05368X04...

Table of Contents