Failure code
E97
Console control problem
E98
Console control problem
EB1
Incoming power frequency out of limits.
EB2
Incoming line voltage above 130 VAC.
EB3
Incoming line voltage below 90 VAC.
EF1
Clogged drain pump.
EF2
To much soap.
EBE
Console control problem
EBF
Console control problem
EF5
NTC temperature for the hot water valve over the limits.
Fault condition
64
Check
Replace the control board.
Replace the control board.
Refer to test (15)
Check voltage at the outlet.
If below 130 VAC replace the
control board.
Check voltage at the outlet.
If above 90 VAC replace the
control board.
Unclog the drain pump.
Advise customer to reduce
the amount of soap they are
using.
Replace the control board.
Replace the control board.
Hot and cold water hoses
switched.