Main Feature; Main Feature; U-Parameter : Monitoring Function; Table 5.1 Functions Of Each Group - Samsung MOSCON-E7 User Manual

Small general-purpose multi-functional inverter
Table of Contents

Advertisement

Refer to the following tables and figures to program the inverter for a
specific application.

5.1 Main Feature

MOSCON-E7's parameters are divided into seven groups and each
group is divided into several subgroups for easier manipulation as
described in Table 5.1.

Table 5.1 Functions of each group

Function
Parameter
(Group)
No.
U0
Monitors inverter operational status.
U1
Monitors the inverter status on the last fault.
Monitoring
(U)
U2
Monitors the previous faults histories.
U3
Monitors parameter check lists..
B0
Controls basic settings of the inverter.
Controls the system initialization and password
Basic Setup
B1
protection.
(B)
B2
Sets the capacity of inverter & motor.
F0
Sets the frequency /speed command.
Frequency
Sets the limit of output frequency. Controls
F1
Control
jump frequency and frequency detection.
(F)
F2
Sets the acceleration/deceleration time.
F3
Sets the S-curve accel/decel time.
S0
Controls the DC braking function.
S1
Controls the speed search function.
S2
Controls the Dwell function.
System
S3
Controls the energy saving operation.
Adjustment
(S)
S4
Controls the slip compensation.
S5
Controls the torque compensation.
S6
Controls the system performance.
C0
Selects the V/f pattern.
H/W
Functionality
C1
Controls carrier frequency.
(C)
C2
Sets the parameters of the motor in use.
5. Parameters
5-3
Function
MOSCON-E7 User's Manual
5-4
H0
Controls the multi-function contact inputs.
H1
Controls the multi-function contact outputs.
I/O Control
H2
Controls the multi-function analog inputs.
(H)
H3
Controls the multi-function analog outputs.
H4
Controls the settings of digital operator.
P0
Controls the motor protective functions.
Controls the protective functions related to
P1
momentary power failure.
Protective
P2
Controls the stall prevention function.
Function
(P)
P3
Controls the over-torque etection/protection.
P4
Controls the fault retry.
P5
Controls the other protective options.

5.1.1 U-Parameter : Monitoring Function

Table 5.2 Operation status

Name
U0.01
Effective Command Frequency
U0.02
Current Output Frequency
U0.03
Output Current in RMS
U0.04
Output Voltage in RMS
U0.05
DC Link Voltage
U0.06
Output Power in 0.1kW
U0.07
Motor Speed in RPM
U0.08
Percentage Output Torque
U0.09
I/O Status
U0.10
Cumulative Power On Time
U0.11
Elapsed Time since Power On
U0.12
S/W Version
Unit
Display
0.01Hz
xx.xx~xxx.x
0.01Hz
xx.xx~xxx.x
0.01A
xx.xA
1V
xxxu
1V
dxxx
0.1kW
Pxx.x
1rpm
xxxx
1%
oxxx
bit
10Hr
xxxx
Min.Sec
mm.ss
r.xxx