Maintenance Console Location
3.43 [1-1] Slot—Card Property - EM type
Programming Manual References
None
Feature Guide References
None
Inter-digit Timer
Specifies the pseudo-answer time.
Value Range
3–15 s
Maintenance Console Location
3.43 [1-1] Slot—Card Property - EM type
Programming Manual References
None
Feature Guide References
None
DTMF Tone—DTMF Inter-digit Pause
Specifies the length of the DTMF inter-digit pause. This allows the telephone company to have enough time
to accept the dialled digits correctly.
Value Range
64 + 16 ´ n (n=0–11) ms
Maintenance Console Location
3.43 [1-1] Slot—Card Property - EM type
Programming Manual References
None
Feature Guide References
None
3.43 [1-1] Slot—Card Property - EM type
PC Programming Manual
371