AC Power Supply Fault Report Delay
Address 0208 - 0209
99 = disabled, 00 - 98 minutes
Domestic Telephone Number
Address 1618 - 1682
Domestic telephone number 1
Domestic telephone number 2
Domestic telephone number 3
Domestic telephone number 4
See Telephone Programming Parameters
If the default value15 is set to the initial digit of the telephone number, domestic telephone
alarm function is disabled. If set to other positions, it marks the end of the telephone number.
Telephone Programming Parameters
Telephone number
required
0
1
2
3
4
5
6
Table 9.1: Telephone Programming Parameters
9.2

Zone Programming

Zone Functions
Each zone can select one of 16 zone functions as well as areas and modules.
Address 0210 - 0361
Zone function # 00
Zone type
Force arm / zone bypass
Silent alarm / chime mode
Bosch Sicherheitssysteme GmbH
Programming input
key
0
1
2
3
4
5
6
Installation Guide
Address Programming | en
Address
0208 - 0209
Address
1618 - 1633
1634 - 1649
1650 - 1665
1666 - 1681
Telephone number
required
7
8
9
*
#
4 seconds pause
15
Address
0210 - 0211
0212
0213
101
Default
60
VDS-A
EN=00-60
Default
15
15
15
15
Programming input
key
7
8
9
11
12
13
15
Default
0 0
3
VDS-A EN=0/2
0
VDS-A EN=0/2