Caution When Data Overwrite Kit (Gp-1050/1060) Is Installed; Hdd Information Display - Toshiba e-STUDIO350 Service Handbook

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO350:
Table of Contents

Advertisement

5.3.3

Caution when Data overwrite kit (GP-1050/1060) is installed

When the Data overwrite kit (GP-1050/1060) is installed, follow the cautions below.
<<Caution when disposing of the HDD>>
Be sure to perform 08-1426 (forcible HDD data clearing) before disposing of the HDD of the equipment.
* When the scrambler board is installed, data in the HDD are overwritten with encrypted data and
erased.
<<Caution when disposing of the SYS board>>
Before the SYS board is disposed, the following codes can be performed.
08-1427 (Forcible NVRAM data all clearing)
08-1428 (Forcible SRAM backup data all clearing)
Caution:
If these codes are performed, the equipment cannot be started up.
5.3.4

HDD information display

This code displays the HDD operation history, which is recorded in the HDD, on the control panel. HDD
failure can be diagnosed or predicted with the information displayed.
1) Display
The following screen is displayed with setting code 08-670.
HDD manufacturer
-
Items supported differ depending on the HDD manufacturer.
-
"---" is displayed on the VALUE, NAV and Worst columns if items are not supported.
e-STUDIO350/352/353/450/452/453
TROUBLESHOOTING
Model name
HDD serial number
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
5 - 136

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents