UNIVERGE SV8100
Place Test Set on output of paging
at chassis port or PGD(2)-U10 ADP
with all external wiring removed.
Yes
External amplifier or PRG
11-01 and PRG 11-10 ~
PRG 11-15
System Maintenance Manual
External Paging Problems
Yes
External
No
page heard on
test set?
Check PRG 11-01 and PRG 11-10 ~
PRG 11-15 for correct access code
(external) for paging.
Access Code
correct?
1. Reset/replace PGD(2)-U10 ADP, and test.
2. Perform Second Initialization, and test; then
perform First Initialization and test.
3. Replace CD-CP00-US and test
using default program.
G1
No
Amplifier
Install amplifier.
provided?
No
Yes
Pass
Retest using
correct access
Done.
code.
Fail
Issue 1.0