OPERATING YOUR HEATER
Fig. 7
HOW TO OPERATE THE HEATER
Temperature Setting:
Press the TEMP
UP or TEMP DOWN button to set the
desired temperature. The temperature
range is 60-90ºF. By pressing the HEATER
button, the heater will default to the
pre-set temperature of 70ºF see Fig. 7.
Humidifier Setting:
CAUTION: Do not
attempt to run humidifier without water
as this will damage the unit and nullify
Fig. 8
the warranty. Before setting/turning ON
humidifier make sure water tank is full.
See "HOW TO REFILL HUMIDIFIER
WATER TANK" on Page 10. Press the
HUMIDIFIER button to turn on/off the
humidifier. Press the humidifier button
once and the unit will begin to produce
humidity until the water is used up. Then,
the LCD will show"ADD WATER." See
Fig. 8. Press twice and the humidifier
will turn off.
Fig. 9
Delay Timer Setting:
Press this button
to set the desired number of hours, and
the unit will stop heating and will not
start heating again until that amount of
time has elapsed, see Fig. 9. For example,
set the Delay Timer for 8 hours before you
go to bed at 10:00 pm, and the unit will
turn on at 6:00 am. You can set the delay
timer number from 1-23 hours. To turn off
the Delay Timer, press the button twice
and the unit will return to normal
heating mode.
Fan Adjust:
Pressing FAN button turns fan from HIGH to LOW. Pressing again
turns fan from LOW to HIGH.
Turn Off The Heater:
Press the power button to turn off all functions. The fan will
continue to run until all of the heat has been expelled and will then turn off. The
COOLING DOWN indicator will show on the LCD display to indicate that the
heater is cooling down.
Auto-Recover Feature
: Should the internal temperature of your heater exceed a
pre-defined limit, the heater will automatically shut itself off, and a red LED light
will illuminate on the Wireless Receiver port on the front of the heater. Check to
make sure nothing is blocking the air intake screen on the back of the heater, or the
heat output vent on the front. Also make sure no other appliances are operating on
the same circuit as the heater. Wait a few minutes for the heater to cool down, then
restart it by pushing the POWER button.
9

OPERACION DE SU CALENTADOR

CÓMO RELLENAR EL TANQUE DE AGUA DEL HUMIDIFICADOR
El tanque de agua está ubicado en la parte superior de la unidad. Para rellenar el
tanque, simplemente retire la cubierta del tanque (Fig. 10) y retire el tanque (Fig. 11),
desenrosque la tapa (Fig. 12) y rellénela con agua limpia (Fig. 13). Vuelva a colocar la
tapa y con cuidado coloque el tanque dentro de la unidad hasta que quede bien
sentado en la base del humidificador.
NOTA: La parte con la tapa va hacia abajo como se muestra en la Fig. 11.
Cubierta
Fig. 10
Fig. 11
del Tanque
Tanque
1. Retire la cubierta del tanque de agua.
2. Saque el tanque de agua.
Fig. 12
Fig. 13
3. Desenrosque la tapa
4. Agregue agua destilada, coloque
la tapa e inserte el tanque según
se muestra en la Fig. 11.