Page 1
Split Type Inverter Room Air Conditioner OPERATION MANUAL MODELS AY-X28MCJ AE-X28MCJ Thank you for selecting SHARP air-conditioner. Please read this manual carefully before operation and keep it for further reference.
Names and functions of each part Indoor unit Air in Air out Front panel Filter Guide louver Wall pipe Bind tape Outdoor unit Connection wire Drainage pipe Remote control Air in Air out...
Operation of remote control Names and functions of remote control buttons Note: Be sure that there are no obstructions between receiver and remote control; Don't drop or throw the remote control; Don't let any liquid in the remote control and put the remote control directly under the sunlight or any place where is very hot.
Operation of remote control Names and functions of remote control buttons NOTE: This wireless remote control is universal and it could be used for many different models.Some buttons on this remote control are not applicable to this model. TIMER AUTO Timer button X-FAN HUMIDITY...
Page 10
Operation of remote control Names and functions of remote control buttons NOTE: This wireless remote control is universal and it could be used for many different models. Some buttons on this remote control are not applicable to this model. X-FAN X-FAN button Press this button to select or cancel X-FAN mode.
Page 12
Operation of remote control When AUTO RUN is selected, the set temperature will not be displayed on the LCD. The unit senses the room temperature automatically to select a suitable running method for room comfort. When TURBO mode is selected the unit will run at super-high fan speed to cool or heat quickly so that the ambient temperature approaches the preset temperature as soon as possible.
Installation dimension diagram Installation dimension diagram Installation dimension diagram Space to the ceiling Above 15cm Above 15cm Above Space to the wall Space to the wall cm cm Above Above Air outlet side Space to the floor Space to the obstruction Air inlet side 30cm Above...
Specifications Model AY-X28MCJ; AE-X28MCJ Function COOLING HEATING Rated Voltage 220-240 V Rated Frequency 50Hz Total Capacity (Min Max) (W) 8000(2100 8400) 8400(1800 9300) Power Input (Min Max) (W) 2660(650 3200) 2860(600 3500) 3500 Rated Input (W) Rated Current (A) 15.53...
Page 28
Outdoor Compressor MITSUBISHI Unit Manufacturer/trademark Compressor Model TNB220FLHMC Compressor Type Rotary L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) 2200 Overload Protector CS01F272H01 Throttling Method Capillary Defrosting Method Automatic Defrosting Operation temp Range ( ) -7 C 43 C Condenser Aluminum fin-copper tube Rows-Fin Gap(mm) 2 -1.4 Coil Length (LXDXW)
Page 30
SHARP APPROVED SERVICE CENTRE VISIT OUR WEBSITE AT www.sharp.net.au OR CALL SHARP CUSTOMER CARE 1300 135 022 (LOCAL CALL COST APPLY WITHIN AUSTRALIA) SHARP CORPORATION OF AUSTRALIA PTY LTD SHARP FOR LOCATION ENQUIRIES WITHIN NEW ZEALAND REGARDING YOUR LOCAL SHARP APPROVED SERVICE CENTRE VISIT OUR WEBSITE AT www.sharp.net.nz...