GE Monogram ZV30R Installation Instructions Manual

30", 36" and 48" professional restaurant style vent hoods
Hide thumbs Also See for Monogram ZV30R:

Advertisement

Quick Links

Installation
Instructions
If you have questions, call 800.GE.CARES or visit our website at: www.monogram.com
30", 36" and 48"
Professional
Restaurant Style
Vent Hoods
Models:
ZV48R
ZV36R
ZV30R
1

Advertisement

Table of Contents
loading

Summary of Contents for GE Monogram ZV30R

  • Page 1 Installation Instructions If you have questions, call 800.GE.CARES or visit our website at: www.monogram.com 30", 36" and 48" Professional Restaurant Style Vent Hoods Models: ZV48R ZV36R ZV30R...
  • Page 2: Installation Instructions

    Installation Instructions BEFORE YOU BEGIN Read these instructions completely and carefully. • IMPORTANT – Save these instructions for local inspector’s use. • IMPORTANT – Observe all governing codes and ordinances. • Note to Installer – Be sure to leave these instructions with the Consumer.
  • Page 3: Table Of Contents

    22-1/2" Hoods may be installed with the shelf or backguard alone, or with both as shown. Model ZV48R 10" 22-1/2" Model ZV30R 47-15/16" 47-15/16" 25" 29-15/16" 12" 29-15/16" 25" 10" 10"...
  • Page 4: Installation Clearances

    Order the duct cover corresponding to your model. Standard Duct Covers SO FF IT 6" Duct Covers Hood Model 32" Min. ZV48R 38" Max. ZV36R ZV30R 12" Duct Covers Hood Model ZV48R ZV36R ZV30R Full-Width Duct Covers 32" Min. 6" Duct Covers 38" Max.
  • Page 5: Installation Height, Duct Cover Accessories

    DETERMINE INSTALLATION HEIGHT, DUCT COVER ACCESSORIES These vent hoods must be installed 30" min. to 36" max. above the standard 36" high cooking surface. When installed with the warming shelf, allow 32" min. to 38" max. clearance. The exact hood installation height is determined by the ceiling height.
  • Page 6: Advance Planning

    ADVANCE PLANNING Ductwork Planning • These vent hoods are equipped for 10" round ductwork. For best performance, use 10" round ductwork on the 48" wide hoods. 30" and 36" hoods may be transitioned to 8" round. • This hood may be vented vertically through upper cabinets, soffit or ceiling.
  • Page 7: Duct Fittings

    8-1/8" x 8". *Actual length of straight duct plus duct fitting equivalent. Equivalent length of duct pieces are based on actual tests conducted by GE Evaluation Engineering and reflect requirements for good venting performance with any ventilation hood. Advance Planning Duct Piece 10"...
  • Page 8: Tools And Materials Required

    TOOLS AND MATERIALS REQUIRED (NOT SUPPLIED) Duct tape Wire cutter/stripper Pencil and tape measure Spirit level Step ladder Pliers Metal Snips REMOVE THE PACKAGING • Remove packages from the “V” shaped cardboard section. Remove shipping pads. • Lift the hood out of the box. IMPORTANT: Lift the hood by grasping the outside edges of the exhaust opening on the top.
  • Page 9: Parts Provided

    PARTS PROVIDED Locate the parts packed with the hood. Duct Transition with Damper Heat Lamp (2 with 48" models) Allen Wrench For Implement Rods HARDWARE PACKAGE Locate and check contents. Screws shown actual size. Note: Hardware appearance may vary slightly. 2 flat washers for wall anchors 6 (3/16") hollow wall anchors...
  • Page 10: Step 1, Determine Ductwork And Wiring Locations

    Installation Instructions STEP 1 DETERMINE HOOD, DUCTWORK AND WIRING LOCATIONS • Use a level to draw the cooktop centerline location. Draw the line to ceiling height. • Measure desired distance from the bottom of the hood to the cooking surface. Note: If you are installing the hood with duct covers, be sure to read “Using Duct Cover Accessories”...
  • Page 11: Step 2A Install Hood Onto Wall

    STEP 2A INSTALL HOOD ONTO WALL SKIP THIS STEP IF INSTALLING BENEATH A SOFFIT OR CABINET, GO TO STEP 2B. • Locate at least 2 vertical studs at the wood support. • Center the supplied wood support, left to right and below the 20"...
  • Page 12: Step 2B, Install Hood Beneath Soffit

    • The 2 x 4 studs must be located as shown in the chart, Dim. A. to accept mounting screws. “A” Centerline to Stud and Keyhole Slots ZV48R 23-9/16" ZV36R 17-9/16" ZV30R 14-9/16" 2" 8-1/8" 7-1/2" 8" 2-9/16" Back of Hood • Drill 1/8" pilot holes into the studs at the locations shown in the top view illustration.
  • Page 13: Step 3 Connect Ductwork

    STEP 3 CONNECT DUCTWORK • Install ductwork, making connections in direction of airflow as illustrated. • Secure joints in ductwork with sheetmetal screws. • Wrap all duct joints with duct tape for an airtight seal. • Use duct tape to seal the flange connection.
  • Page 14: Step 7 Install Filters

    STEP 7 INSTALL FILTERS • Drop grease tray into the hood. The rear tabs should engage the slots in the hood track. STEP 8 INSTALL BACKGUARD AND SHELF INSTALL BACKGUARD: • Remove packaging. • Place backguard against the bottom of the hood to use as a template.
  • Page 15: Step 9, Install Shelf Only

    Installation Instructions STEP 9 INSTALL SHELF “ONLY” • Remove shelf packaging and protective film. • If installing the shelf alone, without the backguard, place shelf against the bottom of the hood and mark screw hole locations “B” on the wall. •...
  • Page 16 1.800.444.1845. Note: Product improvement is a continuing endeavor at General Electric. Therefore, materials, appearance and specifications are subject to change without notice. GE Consumer & Industrial GE Appliances General Electric Company Louisville, KY 40225 ge.com...

This manual is also suitable for:

Monogram zv48rMonogram zv36r

Table of Contents