GE 489 Instruction Manual page 178

Generator management relay
Hide thumbs Also See for 489:
Table of Contents

Advertisement

6.3 MODBUS MEMORY MAP
Table 6–1: 489 MEMORY MAP (SHEET 7 OF 24)
ADDR NAME
489 SETUP / SERIAL PORTS
1010
SLAVE ADDRESS
1011
COMPUTER RS485 BAUD RATE
1012
COMPUTER RS485 PARITY
1013
AUXILIARY RS485 BAUD RATE
1014
AUXILIARY RS485 PARITY
1015
PORT USED FOR DNP
1016
DNP SLAVE ADDRESS
1017
DNP TURNAROUND TIME
489 SETUP / REAL TIME CLOCK
1030
DATE
1032
TIME
1034
IRIG-B TYPE
489 SETUP / MESSAGE SCRATCHPAD
1060
Scratchpad
1080
Scratchpad
10A0
Scratchpad
10C0
Scratchpad
10E0
Scratchpad
489 SETUP / CLEAR DATA
1130
CLEAR LAST TRIP DATA
1131
CLEAR MWh and Mvarh METERS
1132
CLEAR PEAK DEMAND DATA
1133
CLEAR RTD MAXIMUMS
1134
CLEAR ANALOG I/P MIN/MAX
1135
CLEAR TRIP COUNTERS
1136
CLEAR EVENT RECORD
1137
CLEAR GENERATOR INFORMATION
1138
CLEAR BREAKER INFORMATION
SYSTEM SETUP / CURRENT SENSING
1180
PHASE CT PRIMARY
1181
GROUND CT
1182
GROUND CT RATIO
SYSTEM SETUP / VOLTAGE SENSING
11A0
VT CONNECTION TYPE
6
11A1
VOLTAGE TRANSFORMER RATIO
11A2
NEUTRAL V.T. RATIO
11A3
NEUTRAL VOLTAGE TRANSFORMER
SYSTEM SETUP / GEN. PARAMETERS
11C0
GENERATOR RATED MVA
11C2
GENERATOR RATED POWER FACTOR
11C3
GENERATOR VOLTAGE PHASE-PHASE
11C4
GENERATOR NOMINAL FREQUENCY
11C5
GENERATOR PHASE SEQUENCE
SYSTEM SETUP / SERIAL START/STOP
11E0
SERIAL START/STOP INITIATION
11E1
STARTUP INITIATION RELAYS (2-5)
11E2
SHUTDOWN INITIATION RELAYS (1-4)
11E3
SERIAL START/STOP EVENTS
DIGITAL INPUTS / BREAKER STATUS
1200
BREAKER STATUS
DIGITAL INPUTS / GENERAL INPUT A
1210
ASSIGN DIGITAL INPUT
1211
ASSERTED DIGITAL INPUT STATE
1212
INPUT NAME
1218
BLOCK INPUT FROM ONLINE
1219
GENERAL INPUT A CONTROL
121A
PULSED CONTROL RELAY DWELL TIME
121B
ASSIGN CONTROL RELAYS (1-5)
121C
GENERAL INPUT A CONTROL EVENTS
121D
GENERAL INPUT A ALARM
121E
ASSIGN ALARM RELAYS (2-5)
121F
GENERAL INPUT A ALARM DELAY
1220
GENERAL INPUT A ALARM EVENTS
1221
GENERAL INPUT A TRIP
1222
ASSIGN TRIP RELAYS (1-4)
1, 2, 3
See Table footnotes on page 6–33
6-16
RANGE
1 to 254
0 to 5
0 to 2
0 to 5
0 to 2
0 to 3
0 to 255
0 to 100
N/A
N/A
0 to 2
0 to 40
0 to 40
0 to 40
0 to 40
0 to 40
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
10 to 50001
0 to 3
10 to 10000
0 to 2
100 to 30000
100 to 24000
0 to 1
50 to 2000001
5 to 100
100 to 30001
0 to 3
0 to 2
0 to 1
1 to 4
0 to 3
0 to 1
0 to 1
0 to 7
0 to 1
0 to 12
0 to 5000
0 to 1
0 to 250
0 to 4
0 to 1
0 to 2
1 to 4
1 to 50000
0 to 1
0 to 2
0 to 3
489 Generator Management Relay
6 COMMUNICATIONS
STEP
UNITS
FORMAT
1
F1
1
F101
1
F102
1
F101
1
F102
1
F216
1
F1
10
ms
F1
N/A
N/A
F18
N/A
N/A
F19
1
F220
1
F22
1
F22
1
F22
1
F22
1
F22
1
F103
1
F103
1
F103
1
F103
1
F103
1
F103
1
F103
1
F103
1
F103
1
Amps
F1
1
F104
1
: 1 / :5
F1
1
F106
1
: 1
F3
1
: 1
F3
1
F103
1
MVA
F13
1
F3
1
V
F1
1
Hz
F107
1
F124
1
F105
1
F50
1
F50
1
F105
1
F209
1
F210
1
F131
1
F22
1
s
F1
1
F105
1
s
F2
1
F50
1
F105
1
F115
1
F50
1
s
F2
1
F105
1
F115
1
F50
DEFAULT
254
4
0
4
0
0
255
10
N/A
N/A
0
_
_
_
_
_
0
0
0
0
0
0
0
0
0
50001
0
100
0
500
500
0
2000001
100
30001
0
0
0
0
0
0
1
0
0
_
0
0
0
0
0
0
16
50
0
0
1