MIC412TI and MIC412TF Camera | Installation and Operation Manual
Sony Set
The

Sonyset

tab shows the controls required for Creating, Loading, Saving,
Uploading and Downloading SonySet tables in FV protocol only.
A MIC can store 10 Sony Set tables, each containing 10 separate camera controls.
This means that a complete setup for the camera module (shutter speed, gain
level, effect etc) can be saved and loaded back at any time through an input from
the user. These can therefore be used to define certain camera states for different
positions or requirements of an installation, for example, one could be set up for
normal running auto everything, and another set-up for ANPR, with a specified
frame rate and gain etc.
These states could then be toggled by calling them up with an
command.
Bosch Security Systems
SonySet Controls
SonySet Prest Number
This is where the SonySet Preset number is selected, there are 10 options
available relating to 10 complete camera setups.
Get Preset from MIC
This process will query the MIC for the table number as specified in the SonySet
Preset Number list. Each valid command and value will be shown in the table. If
any data is incorrect or the command does not exist the Sony Command column
will display "Invalid". It is not advised to reprogram a MIC with any "Invalid"
commands.
Send Preset to MIC
This will read through the entire table checking for valid commands and respective
values indicating any discrepancies, and then form the commands to send the data
to the MIC. The data is stored to the preset number as indicated in the SonySet
Preset Number in list.
Execute SonySet