7-18 Troubleshooting
Exclamation mark "!" appears to "VGA Display Controller" under the "non-Plug and
Play device" when changed the setting to show hidden devices in menu in the
Device Manager:
This has to do with the server specification and there is no effect to the operation.
Exclamation mark "!" appears to "VGA Display Controller" since OS Standard VGA
driver is not activated in the server.
Warning message appears in POST after implementing ft Remote Management Card:
Did you set "Initialize Remote Management Card"?
H/W Configuration of BMC is corrupted
!! Update BMC H/W Configuration by configuration tool!!
!! Refer to BMC Configuration manual !!
If the message above appears, press F1 key or wait for a while. Then POST
proceeds. Insert NEC EXPRESSBUILDER CD-ROM attached to the server to the
DVD-ROM drive to start NEC EXPRESSBUILDER. Select [Tools] - [Initialize
Remote Management Card] from its main menu to write the sensor information
specific to the server to the card.
A CPU/IO module cannot be integrated:
When a component fails and is reintegrated, the following message may be recorded to the system
event log and the process is stopped. Such event indicates that the component's MTBF is below the
threshold and it is judged that repair is necessary. Thus the reintegration process cannot be
completed. Generally replacement of the component will be required, so contact your sales
representative. If reintegrating the component without repair is required for some reason, contact
NEC Corporation of America's Technical Support or your authorized Sales agent. It is possible to
perform reintegration forcefully.
Source:
ID:
Description:
Distorted display can be seen when screen resolution is changed.
If screen resolution is changed while the entire system is under high load, screen
under changing (distorted display) may be seen.
This is because screen update is taking time to complete due to high load in the
system. This is not because an error is occuring.
The screen will return to normal if you wait awhile.
Duplexed status is not displayed properly.
When one CPU/IO module is reintegrated after the other CPU/IO module is removed
due to the failure or replacement, the status in ESMPRO or RDR Utility and status
LED 2 on the CPU/IO module may not be displayed properly.
Restore normal display with the following procedure.
<Restoration procedure>
srabid
16395
x is now STATE BROKEN / REASON_BELLOW_MTBF ("x" is a
device number.)