IP-Module
IP-Module CFVA-IP
IP-Module CVVA-IP

User manual

Issue 07/2005
Fire Safety & Security Products
Siemens Building Technologies

Advertisement

Table of Contents
loading

Summary of Contents for Siemens IP-Module

  • Page 1: User Manual

    IP-Module IP-Module CFVA-IP IP-Module CVVA-IP User manual Issue 07/2005 Fire Safety & Security Products Siemens Building Technologies...
  • Page 2 Data and design subject to change without notice. Supply subject to availability. © Copyright by Siemens Building Technologies AG Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor. Der Empfänger anerkennt diese Rechte und wird dieses Dokument nicht ohne unsere vorgängige schriftliche Ermächtigung ganz oder teilweise Dritten zugänglich machen oder außerhalb des Zweckes verwenden, zu dem es ihm übergeben worden ist.
  • Page 3: Table Of Contents

    Contents Introduction .....................5 General Safety Precautions ..............6 Ordering data...................7 Ordering data for IP-Module CFVA-IP ............7 Ordering data for IP-Module CVVA-IP ............7 Norms and Directives ................8 Technical data ..................9 Technical data for IP-Module CFVA-IP.............9 Technical data for IP-Module CVVA-IP ..........10 Installing the IP-Module................11 Installing IP-Module type CFVA-IP ............11...
  • Page 5: Introduction

    We wish you every success in using this product. If you have any questions about the product, please contact your local SIEMENS branch office. This IP-Module allows you to display live video images from a dome camera on your PC via an internet connection.
  • Page 6: General Safety Precautions

    Never use the camera and the IP-Module for purposes other than those designated. Repairs and adjustments to the camera and the IP-Module may be done only by authorized personnel. If liquids or objects get into the housing, disconnect the camera and the IP- Module from the power supply and have it checked by your authorized dealer before using it again.
  • Page 7: Ordering Data

    Ordering data Ordering data for IP-Module CFVA-IP Type Item no. Description Weight CFVA-IP 2GF1086-8AL IP-Module for 12 V DC / 24 0.40 kg V DC indoor fix dome camera Extra accessories, not included in the standard supply! PSU230-12 2GF1800-8BE 12 V DC camera power 0.12 kg...
  • Page 8: Norms And Directives

    The product satisfies the requirements of the EU Electromagnetic Compatibility Directive 89/336/EEC. The EU declarations of conformity can be made available to the relevant authorities Siemens Building Technologies Fire & Security Products GmbH & Co. oHG Siemensallee 84 D-76187 Karlsruhe...
  • Page 9: Technical Data

    Technical data Technical data Technical data for IP-Module CFVA-IP Electrical supply 12 V DC/24 V AC Power requirement max. 6.0 W Operating temperature range -10 – +45 °C, max. relative humidity 90% Storage temperature range -20 – +60 °C Dimensions (H x Ø) 35.5 x 140 mm...
  • Page 10: Technical Data For Ip-Module Cvva-Ip

    Technical data Technical data for IP-Module CVVA-IP Electrical supply 12 V DC/24 V AC Power requirement max. 6.0 W Operating temperature range -10 – +50 °C, max. relative humidity 90% Storage temperature range -20 – +60 °C, max. relative humidity 70% Dimensions (H x Ø)
  • Page 11: Installing The Ip-Module

    2. Mount the IP-Module to the ceiling/wall. 3. Connect the BNC cable (12) to the connector socket (4) in the IP-Module. Installation and connection of the dome camera 4. Connect the video output from the dome camera to the BNC cable video input (11).
  • Page 12: Installing Ip-Module Type Cvva-Ip

    Installing the IP-Module 7. Place the camera body on the IP-Module and screw both units together using the two screws supplied. 8. Connect the LAN cable to the RJ45 socket (7). 9. Connect the (12 V DC / 24 V AC) electrical supply (8).
  • Page 13 (side aperture or base aperture). 6. Connect the LAN cable to the RJ45 socket (6). 7. Connect the Y cable supplied to the connector socket (3) in the IP-Module. 8. Connect the electrical supply to the connector socket (4).
  • Page 14: Establishing Initial Communication With The Device

    First of all, enter the client PC IP address from which the device is to be accessed. 1. To do so, open the command prompt screen via the Windows Start Menu. 2. Type ipconfig and press the Enter key. Siemens Building Technologies Fire Safety & Security Products...
  • Page 15 4. Check that there is communication with the device by typing ping 192.168.100.100. 5. You must now allocate the desired IP address to the device via the device's homepage. See section 10.1 Changing the device IP address. Siemens Building Technologies Fire Safety & Security Products...
  • Page 16: Checking Device Accessibility

    = 192.168.100.100 if the IP address set by the factory is used xxx.xxx.xxx.xxx = the IP address you have allocated to the device; e. g. 141.73.31.3. 3. Press the Enter key. Siemens Building Technologies Fire Safety & Security Products...
  • Page 17: Device Homepage

    1. Start the Web-Cam IP Manager by loading IP Manager.exe. This application can be found on the CD. The Web-Cam IP Manager program window will open: Siemens Building Technologies Fire Safety & Security Products...
  • Page 18 3. Select the device whose homepage you want to call up. 4. Click on the Home page of selected device... button The homepage of the selected device is now called up. See section 9.2: Components of the device homepage. Siemens Building Technologies Fire Safety & Security Products...
  • Page 19: Components Of The Device Homepage

    Buttons for displaying live video images. See section 15.1: Displaying live video Submenu Language selection list box. Standard setting: English Main menus Display area for live video images. See section 15.1: Displaying live video Siemens Building Technologies Fire Safety & Security Products...
  • Page 20: Configuring Network Settings

    3. Enter the desired settings in this dialogue window. 4. The settings are described in detail below. 5. Click on Save. 6. Restart your IP-Module. See section 14: Restarting the IP Module. The network settings will be adopted. Firmware Version...
  • Page 21: Changing The Device Ip Address

    (IP address, subnet mask and gateway, if applicable). 4. Restart your IP-Module. See section 14: Restarting the IP Module. Manual IP address and subnet mask allocation 1. Call up the device homepage. See section 9.1: Calling up the device homepage.
  • Page 22: Changing The Ip Address Using The Web-Cam Ip Manager

    5. Enter the gateway in the list box. See section 10: Configuring network settings. 6. Restart your IP-Module. See section 14: Restarting the IP Module. Example If you set the device IP address to, for example, 141.73.31.3 and the subnet mask to 255.255.255.128, the device can be accessed by a client PC with IP address...
  • Page 23 The settings will be adopted immediately. This process takes about 40 seconds. Next, the device homepage will be displayed, allowing you to check the entries in Network settings in the Configuration menu. Siemens Building Technologies Fire Safety & Security Products...
  • Page 24: Configuring Image Parameters

    3. Enter the desired settings in this dialogue window. Name Enter a name for the video source here. This is the name that will be overlaid on the live video image if you have activated the appropriate setting. Siemens Building Technologies Fire Safety & Security Products...
  • Page 25: Configuring Jpeg Encoder Settings

    The values shown relate to a color image of average complexity. 1. Call up the device homepage. See section 9.1: Calling up the device homepage. 2. Select Image parameters in the Configuration menu. The Image parameters dialogue window opens: Siemens Building Technologies Fire Safety & Security Products...
  • Page 26 The following options are available: – (no text overlay) Small Large 7. Select the input signal from the options in the Video Standard list box. The following options are available: PAL/CCIR NTSC/EIA 8. Click on Save. Siemens Building Technologies Fire Safety & Security Products...
  • Page 27: Setting The Date And Time

    The time and date that were current when the device start page was loaded appear in the relevant boxes. You can set the device's built-in real-time clock here. 3. Choose the desired settings from the list of options for each field. 4. Click on Save. Siemens Building Technologies Fire Safety & Security Products...
  • Page 28: Configuring User Names And Passwords

    The Security dialogue window opens: Security Fig. 6 3. Enter the desired user name (max. 32 characters). 4. Enter the desired password (max. 32 characters). 5. Confirm the password. 6. Click on Save. Siemens Building Technologies Fire Safety & Security Products...
  • Page 29: Restarting The Ip Module

    2. Enter the time in the box (HH:MM), e. g. 12:00. 3. Click on Save. The device will restart at the set time every day. 4. Restart the device to adopt the new settings. Siemens Building Technologies Fire Safety & Security Products...
  • Page 30 The time-out value must be a multiple of the cycle time (the value entered in Frequency). In the event of an unexpected system problem, this ensures the device becomes available again after 2 to 3 minutes. 5. Restart the device to adopt the new settings. Siemens Building Technologies Fire Safety & Security Products...
  • Page 31: Live Video

    Java Runtime. Java Runtime can be found on the CD supplied. Displaying live video 1. Call up the device homepage. See section 9.1: Calling up the device homepage. The live video image is displayed using the standard settings: Siemens Building Technologies Fire Safety & Security Products...
  • Page 32: Setting Live Video Resolution

    2. Choose Save image to in the context menu (right-click with the mouse). The Save image dialogue window opens. 3. Indicate the storage location and the image file name here. 4. Click on the Save button. Siemens Building Technologies Fire Safety & Security Products...
  • Page 33: Establishing Access To The Device Via Internet

    IP address may have changed. When the connection is terminated, this IP address becomes available for use by another device and is allocated to another connection that is established via the ISP. When the Siemens Building Technologies Fire Safety & Security Products...
  • Page 34 If it is now attempted to establish a connection to your domain name, www.myWebCam.de for example, the connection to your router will be built up via your ISP. The router must be configured to pass all incoming requests to the device. Siemens Building Technologies Fire Safety & Security Products...
  • Page 35: Embedding Live Video Images In A Dedicated Html Page

    <body> <img src="http://141.73.46.35/cgi-bin/livejpeg?size=1> <body> <html> Embedding still pictures Still pictures can be embedded in a dedicated HTML page as follows, e. g.: <IMG SRC="http://192.168.1.100/cgi-bin/livejpeg" BORDER=8> Use the parameters in the table above. Siemens Building Technologies Fire Safety & Security Products...
  • Page 36: Service Mode

    For this reason, you should now re-assign a permanent IP address to the device via the device homepage. See section 9.1.1: Changing the device IP address via the device homepage. Siemens Building Technologies Fire Safety & Security Products...
  • Page 37: Index

    Configuring passwords, 28 EMC Directive, 8 EU Directive, 8 Resolution Exploded view IP-Module Setting live video resolution, 32 Exploded view of IP-Module CFVA-IP, 11 Exploded view of IP-Module CVVA-IP, 12 Saturation Configuring saturation, 24 Flip picture, 24 Service mode, 36...
  • Page 38 Herausgegeben von © Copyright by Siemens Building Technologies Siemens Building Technologies AG Fire & Security Products GmbH & Co. oHG Liefermöglichkeiten und technische Änderungen vorbehalten. D-76181 Karlsruhe Gedruckt in der Bundesrepublik Deutschland auf umweltfreundlich chlorfrei gebleichtem Papier. www.sbt.siemens.com Dokument Nr.

This manual is also suitable for:

Ip-module cfva-ipIp-module cvva-ip

Table of Contents