To change the size of integrated trace files:
1
In the Hitachi Network Objectplaza Trace Library setup menu, type 1 and
.
then press the Enter key.
A screen to set the size of the integrated trace file will appear. The
current value is displayed in Current Size (KB).
2
Enter the desired size in New Size (KB).
.
The specifiable range is between 8 KB and 8192 KB, with a default of 256.
Set this to a value larger than that set in step 2 of
Size Per Monitoring Interval Duration on page
setting a value of 4096 when collecting an integrated trace.
If you do not want to change the integrated trace file size, leave New
Size (KB) blank, type !, and then press the Enter key to return to the
Hitachi Network Objectplaza Trace Library setup menu.
3
Press the Enter key.
.
The new setting is applied and the Hitachi Network Objectplaza Trace
Library setup menu appears again.
Changing the Number of Integrated Trace Files
The following procedure shows how to change the number of integrated trace
files.
To change the number of integrated trace files:
1
In the Hitachi Network Objectplaza Trace Library setup menu, type 2 and
.
then press the Enter key.
A screen to set the number of integrated trace files will appear. The
current value is displayed in Current Number (KB).
2
Enter the desired number in New Number (KB).
.
You can specify a value from 1 to 16. The default is 4. The value set here
becomes the maximum of n in /var/opt/hitachi/HNTRLib2/spool/
hntr2n.log. The recommended value for integrated trace collection is 8.
3-80
Creating an HDLM Environment
Hitachi Dynamic Link Manager User Guide (for AIX(R))
Changing the Buffer
3-81. We recommend