Configuring Switch Settings on the Hot Swap Subsystem

Switch setting combinations are given in the table below.
Switch
2
1
I
C Bus Setting
2
2
I
C Bus Setting
3
High/Low Addresses
4
SCSI Address Zero
Sets middle shelf in cage to
SCSI ID 0.
5
Remote Start
Determines control of the
hot swap disk module
power-on sequence.
6
Upper/Lower Cage
Identifies cage location.
This is important information
for the SCSI addresses and
for the I
Off
On
1
2
3
4
UPPER
CAGE
5
6
1
2
LOWER
3
CAGE
4
5
6
Function
2
C bus.
Always set to Off
Always set to Off
Always set to Off
On: Sets middle shelf in the cage (shelf 2 or shelf 5) to
SCSI ID 0.
Off: Sets middle shelf to normal SCSI address
sequence.
See SCSI Address Settings table below for description
of settings.
On: Internal control: Upper cage is set to delayed start
and lower cage is set to power-on at startup.
Off: Power-on sequence is determined by the disk array
controller.
On: Lower cage
Off: Upper cage
See SCSI Address Settings table below for description
of settings.
Settings