HP P2000 Reference Manual page 11

Msa system event descriptions
Hide thumbs Also See for P2000:

Advertisement

78
Warning
The controller could not use an assigned spare for a vdisk because the spare's capacity is too small. This
occurs when a vdisk's status becomes critical and all global spares are too small or (if the dynamic spares
feature is enabled) all disks are too small.
Recommended actions
Replace existing spares or add spares with enough capacity to replace the smallest disk in the vdisk.
The vdisk size is limited by its disk with the least capacity.
79
Info.
A trust operation has completed for the indicated vdisk. Be sure to complete the trust procedure as
documented for the trust command in the CLI reference guide.
Recommended actions
No action required.
80
Info.
The controller enabled or disabled the indicated parameters for one or more disks.
Recommended actions
No action required.
81
Info.
The current controller has unkilled the partner controller. The other controller will restart.
Recommended actions
No action required.
83
Info.
The partner controller is changing state (shutting down or restarting).
Recommended actions
No action required.
84
Warning
The current controller has forced the partner controller to fail over.
Recommended actions
See
Resources for diagnosing and resolving problems
86
Info.
Host-port or disk-channel parameters have been changed.
Recommended actions
No action required.
87
Warning
The mirrored configuration retrieved by this controller from the partner controller has a bad cyclic
redundancy check (CRC). The local flash configuration will be used instead.
Recommended actions
Restore the default configuration by using the restore defaults command, as described in the CLI
reference guide.
on page 3.
HP P2000 G3 MSA System Event Descriptions Reference Guide
11