Step 10: Power on the devices

After the MSA and its storage enclosures are installed and connected to the SAN,
power up all of the devices in the SAN and verify that they are operating properly.
1. Apply power to each UPS.
2. Apply power to each external Fibre Channel switch.
3. Apply power to each attached storage enclosure.
4. Power on the MSA by pressing the power/standby button on the front panel.
5. Wait (up to four minutes) for the MSA to complete its startup routine.
Note:
the two controllers is compared. If the versions are mismatched, the system prompts to
clone the firmware on the controller with the latest version (higher number) over to the
controller with the earlier version (lower number) firmware. The following message is
displayed on the LCD panel of the controller with the earlier firmware:
Press the > button on the LCD panel to clone the firmware. In dual-controller
configurations, the firmware on the controllers
6. Press the ^ and v LCD panel message buttons on the front of each MSA
Note:
displayed. If you power up the server before the MSA has completed its power-on
sequence, your server may not see the MSA properly.
7. Apply power to the servers in the SAN with access to the MSA, start the
HP StorageWorks 1500 Modular Smart Array Installation Guide
The LED on the power/standby button changes from amber to solid green,
indicating that the MSA has been powered on.
In dual-controller configurations, each time the MSA is restarted, firmware on
07 CLONE FIRMWARE? '<'= NO, '>'= YES
controller to review the startup messages and look for the following message:
Startup Complete
Proceed to the next step only after the
operating system, and log on as user with administrative control.
Installation Procedures - All Deployments
must
be the same version.
message is
Startup Complete
57