Whirlpool YGMH6185XVB Installation Instructions Manual
Whirlpool YGMH6185XVB Installation Instructions Manual

Whirlpool YGMH6185XVB Installation Instructions Manual

Installation guide
Hide thumbs Also See for YGMH6185XVB:
Table of Contents

Advertisement

Available languages

Available languages

MICROWAVE HOOD COMBINATION
This product is suitable for use above electric or gas cooking products up to and including 36" (91.4 cm) wide. See "Installation
Requirements" section for further notes.
These installation instructions cover different models. The appearance of your particular model may differ slightly from the illustration in
these installation instructions.
DE L'ENSEMBLE FOUR À MICRO-ONDES/HOTTE
Ce produit est conçu pour l'utilisation au-dessus d'appareils de cuisson électriques ou à gaz de 36" (91,4 cm) de largeur ou moins. Voir
la section "Exigences d'installation" pour d'autres remarques.
Ces instructions d'installation sont valables pour plusieurs modèles. Il se peut que l'apparence de votre propre modèle soit légèrement
différente de celle montrée sur les illustrations dans ce document.
MICROWAVE HOOD COMBINATION SAFETY.......................1
INSTALLATION REQUIREMENTS............................................2
Tools and Parts .......................................................................2
Remove Cardboard Template ................................................2
Location Requirements ...........................................................2
Product Dimensions................................................................3
Electrical Requirements ..........................................................3
INSTALLATION INSTRUCTIONS..............................................4
Remove Mounting Plate..........................................................4
Rotate Blower Motor...............................................................4
Locate Wall Stud(s) .................................................................6
Mark Rear Wall ........................................................................7
Drill Holes in Rear Wall............................................................7
Attach Mounting Plate to Wall ................................................8
Prepare Upper Cabinet ...........................................................8
Install Damper Assembly ........................................................9
Install the Microwave Oven.....................................................9
Complete Installation ........................................................... 10
VENTING DESIGN SPECIFICATIONS ................................... 11
ASSISTANCE........................................................................... 12
Replacement Parts............................................................... 12
Accessories .......................................................................... 12

MICROWAVE HOOD COMBINATION SAFETY

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
W10344701B
INSTALLATION INSTRUCTIONS
INSTRUCTIONS D'INSTALLATION
Table of Contents / Table des matières
Your safety and the safety of others are very important.
DANGER
EXIGENCES D'INSTALLATION.........................................................13
Outillage et pièces...........................................................................13
Dépose du gabarit de carton ..........................................................14
Exigences d'emplacement..............................................................14
Dimensions du produit ....................................................................14
Spécifications électriques ...............................................................15
INSTRUCTIONS D'INSTALLATION ..................................................15
Dépose de la plaque de montage...................................................15
Réorientation du moteur du ventilateur ..........................................15
Tracé sur le mur arrière ...................................................................18
Perçage de trous dans le mur arrière..............................................19
Fixation de la plaque de montage sur le mur .................................19
Préparation du placard mural..........................................................20
Installation du module du clapet anti-reflux....................................20
Installation du four à micro-ondes ..................................................21
Achever l'installation........................................................................22
SPÉCIFICATIONS DU CIRCUIT D'ÉVACUATION ...........................23
ASSISTANCE......................................................................................24
Pièces de rechange.........................................................................24
Accessoires .....................................................................................24
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.

Advertisement

Table of Contents
loading

Summary of Contents for Whirlpool YGMH6185XVB

  • Page 1: Table Of Contents

    MICROWAVE HOOD COMBINATION INSTALLATION INSTRUCTIONS This product is suitable for use above electric or gas cooking products up to and including 36" (91.4 cm) wide. See “Installation Requirements” section for further notes. These installation instructions cover different models. The appearance of your particular model may differ slightly from the illustration in these installation instructions.
  • Page 2: Installation Requirements

    INSTALLATION REQUIREMENTS Tools and Parts Remove Cardboard Template Tools Needed The cardboard piece from the top of the microwave oven packaging is perforated. The piece inside the perforation is for use Gather the required tools and parts before starting installation. as a rear wall template.
  • Page 3: Product Dimensions

    Installation Dimensions Electrical Requirements NOTE: The grounded 3 prong outlet must be inside the upper cabinet. See “Electrical Requirements” section. WARNING 12" (30.5 cm) min. 14" (35.6 cm) max. upper cabinet and 30" side cabinet depth (76.2 cm) min. Electrical Shock Hazard 30"...
  • Page 4: Installation Instructions

    INSTALLATION INSTRUCTIONS 4. Lift blower motor out of microwave oven. Remove Mounting Plate Depending on your model, the mounting plate may be in the foam packaging, or it may be attached to the back of the microwave oven. NOTE: To avoid possible damage to the work surface, cover the work surface.
  • Page 5 Roof Venting Installation Only 1. Repeat Step 1 from “Wall Venting Installation Only.” 6. Reattach blower motor to back of microwave oven with 2 screws removed in Step 3 of “Wall Venting Installation Only.” 2. Repeat Step 2 from “Wall Venting Installation Only.” Securely tighten screws.
  • Page 6: Locate Wall Stud(S)

    Locate Wall Stud(s) NOTE: If no wall studs exist within the cabinet opening, do not 1. Using a stud finder, locate the edges of the wall stud(s) within install the microwave oven. the opening. See illustrations in “Possible Wall Stud Configurations.” 2.
  • Page 7: Mark Rear Wall

    5. With the support tabs facing forward (see illustrations in “Locate Wall Stud(s)” section), align the mounting plate center Mark Rear Wall markers to the centerline on the wall, making sure its bottom The microwave oven must be installed on a minimum of 1 wall edge is aligned to the horizontal line drawn in Step 3, and that stud, preferably 2, using a minimum of 1 lag screw, preferably 2.
  • Page 8: Attach Mounting Plate To Wall

    6. Check alignment of mounting plate, making sure it is level. Installation for Wall Stud at One End Hole (Figure 3) 7. Securely tighten all lag screws and bolts. 1. Drill a 3/16" (5 mm) hole into the wall stud at the end hole Wall Stud at One End Hole (Figure 3) marked in Step 3 of “Mark Rear Wall.”...
  • Page 9: Install Damper Assembly

    5. Cut the 1 " (3.8 cm) diameter hole at the circular shaded area “G” on the template. This hole is for the power supply cord. Install the Microwave Oven NOTE: If upper cabinet is metal, the supply cord bushing needs to be installed around the supply cord hole, as shown.
  • Page 10: Complete Installation

    NOTE: If microwave oven does not need to be adjusted, skip 2. Connect vent to damper assembly. steps 7-9. 7. If adjustment is required, rotate microwave oven downward. Using 2 or more people, lift microwave oven off of mounting plate, and set aside on a covered surface. 8.
  • Page 11: Venting Design Specifications

    VENTING DESIGN SPECIFICATIONS This section is intended for architectural designer and Rectangular to Round Transition builder/contractor reference only. NOTE: The minimum 3" (7.6 cm) clearance must exist between NOTES: the top of the microwave oven and the rectangular to round transition piece so that the damper can open freely and fully.
  • Page 12: Assistance

    Recommended Vent Length x 10 (8.3 x 25.4 cm) rectangular or 6 (15.2 cm) round vent 6" (15.2 cm) vent system = 73 ft (22.2 m) total " " " should be used. The total length of the vent system including straight vent, elbow(s), transitions and wall or roof caps must not exceed the 6 ft (1.8 m) equivalent of 140 ft (42.7 m) for either type of vent.
  • Page 13: Sécurité De L'ensemble Four À Micro-Ondes/Hotte

    SÉCURITÉ DE L’ENSEMBLE FOUR À MICRO-ONDES/HOTTE Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité.
  • Page 14: Dépose Du Gabarit De Carton

    Dimensions à respecter lors de l'installation Dépose du gabarit de carton REMARQUE : La prise de courant à 3 alvéoles reliée à la terre doit être située à l'intérieur du placard mural. Voir la section Le morceau de carton du dessus de l'emballage du four à micro- “Spécifications électriques”.
  • Page 15: Spécifications Électriques

    Spécifications électriques AVERTISSEMENT INSTRUCTIONS DE LIAISON À LA TERRE Pour tout appareil ménager connecté par un cordon de courant électrique : Il faut que le four à micro-ondes soit relié à la terre. En cas de court-circuit électrique, la liaison à la terre réduit le Risque de choc électrique risque de choc électrique car le courant électrique dispose d’un itinéraire direct d’acheminement à...
  • Page 16 3. Retirer les 2 vis fixant le moteur du ventilateur à l'arrière du Pour une installation avec décharge à l'extérieur à four à micro-ondes. travers le toit seulement 1. Répéter l'étape 1 de “Pour une installation avec décharge murale seulement”. 2.
  • Page 17: Identifier La Position Du/Des Poteau(X) Du Colombage Mural

    Identifier la position du/des poteau(x) du colombage mural REMARQUE : S'il n'y a aucun poteau du colombage mural dans 1. Utiliser un détecteur magnétique de clou/vis pour localiser la zone délimitée par l'ouverture dans le placard mural, ne pas dans l'ouverture les rives du/des poteau(x) du colombage installer le four à...
  • Page 18: Tracé Sur Le Mur Arrière

    Tracé sur le mur arrière Le four à micro-ondes doit être fixé sur au moins un poteau du 5. Une fois les brides de support orientées vers l'avant (voir les colombage mural, et de préférence sur 2 poteaux; on utilise pour illustrations de la section “Identification de la position du/des cela au moins 1 vis d'ancrage, et de préférence 2 vis.
  • Page 19: Perçage De Trous Dans Le Mur Arrière

    2. Engager un écrou articulé sur chaque vis par l'arrière de la plaque de montage. Veiller à disposer de suffisamment Perçage de trous dans le mur arrière d'espace pour que les écrous articulés puissent traverser le En plus de la fixation sur au moins un poteau du colombage, on panneau de gypse et se déployer à...
  • Page 20: Préparation Du Placard Mural

    6. S'il est possible de fixer également l'appareil sur un second 5. Percer le trou de diamètre 1½" (3,8 cm) dans la zone circulaire poteau du colombage mural, insérer une vis d'ancrage dans grisée “G” du gabarit. Ce trou est utilisé pour le passage du l'autre trou percé...
  • Page 21: Installation Du Four À Micro-Ondes

    Installation du four à micro-ondes 4. Alors que l'avant du four à micro-ondes est encore incliné, AVERTISSEMENT enfiler le cordon d'alimentation à travers le trou de passage percé dans le fond du placard mural. Risque du poids excessif Utiliser deux ou plus de personnes pour déplacer et installer le four à...
  • Page 22: Achever L'installation

    Pour une installation avec décharge à l'extérieur à Achever l'installation travers le toit seulement 1. Installer les filtres. Voir les Instructions d’utilisation pour la mise en place des filtres. 1. Insérer le module du clapet anti-reflux à travers l'ouverture découpée dans le placard mural, de telle manière que la patte longue du module du clapet anti-reflux puisse glisser sous les AVERTISSEMENT pattes d'arrimage relevées de la plaque de support du clapet.
  • Page 23: Spécifications Du Circuit D'évacuation

    SPÉCIFICATIONS DU CIRCUIT D'ÉVACUATION Cette section présente de l'information de référence uniquement, Raccord de transition rectangulaire/rond à l'intention des architectes/concepteurs et constructeurs. REMARQUE : On doit disposer d'un espace libre de 3" (7,6 cm) REMARQUES : ou plus entre le sommet du four à micro-ondes et le raccord de transition rectangulaire/rond pour que le clapet anti-reflux puisse Les matériaux du circuit d'évacuation nécessaires à...
  • Page 24: Assistance

    Longueur recommandée du circuit d'évacuation On doit utiliser un conduit rectangulaire de 3¼" x 10" (8,3 x Circuit d’évacuation de dia. 6" (15,2 cm) = longueur totale 25,4 cm), ou un conduit rond de dia. 6" (15,2 cm). 73 pi (22,2 m) La longueur totale du circuit d'évacuation, ceci incluant les sections de conduit rectilignes, coude(s), raccords de transition et bouche de décharge murale ou sur toit, ne doit pas dépasser...

This manual is also suitable for:

Ygmh6185xvs