Download Print this page
ABB Stanilite Series Installation Manual
ABB Stanilite Series Installation Manual

ABB Stanilite Series Installation Manual

Weatherproof ip65 3cct led batten

Advertisement

Quick Links

DIP Switch Setting
Detection Area
(Sensitivity)
Hold Time
1
2
3
4
100%
ON
ON
I
ON
ON
ON
75%
-
ON
II
-
ON
ON
50%
ON
-
III
ON
-
ON
25%
-
-
IV
-
-
ON
V
ON
ON
VI
-
-
Disable* means the daylight sensor does not work. it will turn on light once motion is detected
regardless of ambient light.
Override Function
Turn power off, quick switch ON/OFF sensor 3 times (ON-OFF-ON-OFF-ON) within 2sec to override
sensor function. Lights will blink 3 times and then switch ON all the time. Power off and on again to
recover sensor function.
Initialization
After power on, the sensor automatically turns on light at 100% brightness. After 10sec, it turns off the
light. During the initialization, the sensor is not able to detect movement.
Factory Setting
Detection area: 100%, Hold Time: 5S, Daylight Sensor: Disable
Troubleshooting guide
No. Fitting
Fault
type
1
Standard
LEDs do not light up when connected to
Nexus LX
mains
Nexus RF
2
Nexus LX
Indicator LED is flashing green but AC LED
lamp does not come on when connected to
mains
3
Nexus LX
Indicator LED is flashing green but lamp
does not come on when test switch is
pressed
4
Nexus LX
Indicator LED does not light up red after
the commissioning
5
Standard
LEDs are lit momentarily when test switch
Nexus LX
is pressed or when mains fail
Nexus RF
6
Nexus LX
Indicator LED is constant green
7
Nexus LX
Fitting LED is not flashing yellow/orange
Nexus RF
under wink node command
ABB Australia Pty Limited
For enquiries
ABB contact centre: 1800 60 20 20
E-mail: AU-ABB-Stanilite@abb.com
www.stanilite.com.au
Daylight Sensor
5
6
7
8
5S
I
ON
ON
ON
2 LUX
30S
II
ON
ON
-
10 LUX
90S
III
-
ON
-
30 LUX
5 min
IV
ON
-
-
50 LUX
-
20 min
V
-
-
-
Disable*
-
30 min
Possible causes
AC supply not connected or turned off; or
Switch active turned off; or
LED strips connections.
Switch active turned off; or
LED strips connections; or
Missing loop from unswitched to switched active
Battery pack not connected or faulty;
or Test switch damaged
Battery pack not connected; or
LED wire not properly inserted into the terminal
Battery not fully charged (allow up to 24 hours);
or Battery pack damaged
Fitting self checks fail - return to manufacturer
Fitting is not receiving communication signal
Check data cable wiring path and cable or RF
connections
Refer to Nexus LX/RF user and technical guide
© Copyright 2023 ABB. All rights reserved. 9AKK108468A4578- C - Aug 2023
INSTALL ATION MANUAL
Stanilite®
Weatherproof IP65 3CCT LED batten
Please read this document thoroughly before
commencing installation and retain for future
reference. Contact ABB customer service in
Australia on 1800 60 20 20 if you need any
assistance. The installation instructions were
correct at the time of print. To reflect changes in
technology and Australian standards; ABB
reserves the right to amend the instructions
without notice. Updated document can be found
on the Stanilite website.
Safety warning
Disconnect mains supply before installing,
servicing or maintaining this luminaire.
To be installed by a qualified electrician in
accordance with AS/NZS 3000 wiring regulations.
Ensure that the rated voltage and frequency of
the luminaire is compatible with the electrical
supply.
As the installer, it is your responsibility to ensure
compliance with all relevant building and safety
codes. Refer to the applicable standards for the
relevant rules.
3CCT (Correlated color temperature)
For this colour select batten,
the slide switch located on
the gear tray allows the
2700K 4 000K 6500K
change of
colour temperature.
Inrush Current
AC: Imax: 15A, Time: 100 µs
Emergency: Imax: 24.5A, Time: 100 µs
This document covers
What's inside the box
Safety warning
Weatherproof LED batten
Installation instructions
Installation manual
Warranty information
Troubleshooting guide
Important to note:
The luminaire only to be installed outside arms
reach.
Do not stare into the LED light beam.
The light source of this luminaire is not
replaceable; when the light source reaches its
end of life the whole luminaire shall be
replaced.
The only user serviceable parts is battery pack
in emergency luminaire.
The recommend mains cable size is minimum
4AWG or 1.5mm2.
This luminaire is a class I product and must be
earthed.
This luminaire is rated IP65, this must be
maintained during wiring and installation.
This product is designed for indoor and
outdoor use.
Not suitable
for installations
where exposure
to direct sunlight
may occur.
Dimensions:
SIZE
L
W
H
B
2FT
655
130
88
420
4FT
1265
130
88
905
Doc no. 29-01347_C

Advertisement

loading

Summary of Contents for ABB Stanilite Series

  • Page 1 ABB Australia Pty Limited AC: Imax: 15A, Time: 100 µs For enquiries Emergency: Imax: 24.5A, Time: 100 µs ABB contact centre: 1800 60 20 20 E-mail: AU-ABB-Stanilite@abb.com www.stanilite.com.au © Copyright 2023 ABB. All rights reserved. 9AKK108468A4578- C - Aug 2023 Doc no. 29-01347_C...