GE Arctica G LINE PHG25PGT Series Technician Manual page 5

Side-by-side dual evaporator refrigerators with electronic touch controls

Advertisement

DISCONNECT POWER CORD BEFOR E SERVICING
IMPORTANT - RECONNECT ALL GROUNDING DEVICES
All parts of this appliance capable of conducting
electrical current are grounded. If grounding wires,
screws, straps, clips, nuts or washers used to
complete a path to ground are removed for service,
they must be returned to their original position and
properly fastened.
ELECTRICAL SPECIFICATIONS
Thermistor: kilo-Ohm resistance ....... @-18°C ............62.79
......................................................................................@ 3°C ................24.48
.................................................................................... @25°C ...............10.00
Defrost Control ............................................ 60hrs @ 45 min
Overtemperature Thermostat ................................. 60-43°C
Defrost Thermistor .....................................................18.3°C
Maximum Current Leakage .................................... 0.75 mA
Maximum Ground Path Resistance .....................0.14 Ohms
NO LOAD PERFORMANCE
Control Position MID/MID
and Ambient of: ........................................ 18°C
Fresh Food, °C ...................................................... 1-4
Frozen Food, °C ...................................... -19/-16
Run T ime, % ........................................... <80
REFRIGERATION SYSTEM
Refrigerant Charge (R134a) .......................................0.184 kg
Compressor ......................214.8 W, 733 BTU/hr @ 3000 RPM
Minimum Compressor Capacity .......................... 22 inches Hg
.............................................................................................................74.5 kPa
........................................................................................................ 0.745 bar
Minimum Equalized Pressure
@ 21°C ...............................................................290 to 310 kPa
@ 32°C ................................................................352 to 372 kPa
Technical Data
IMPORTANT SAFETY NOTICE
This information is intended for use by individuals
possessing adequate backgrounds of electrical,
electronic and mechanical experience. Any attempt
to repair a major appliance may result in personal
injury and property damage. The manufacturer or
seller cannot be responsible for the interpretation of
this information, nor can it assume any liability in
connection with its use.
INSTALLATION
Minimum clearance required for air circulation:
w/ no door openings
AIR FLOW
32°C
1-4
-19/-16
=100
– 5 –
TOP
.......................................................2.54
SIDES
....................................................0.32
REAR
.....................................................1.27
0.85cm
cm
cm
cm