18.2.4 Rapid reading of alarms
The last alarm can be displayed even if the programme selector is not in the tenth position (diagnostics) or if the
appliance is in normal operating mode (e.g. during the execution of the washing programme):
→ Press the START/PAUSE button and the nearest option button simultaneously (as if you were entering
DIAGNOSTIC mode) for at least 2 seconds: the LEDs initially switch off, and then display the flashing
sequence indicating the last alarm.
→ The alarm continues to be displayed for the amount of time required, and then the display returns to its
normal operation.
→ The alarm reading system is as described in sect. 8.2.
→ While the alarm is being displayed, the appliance continues to perform the cycle or, if in the programme
selection phase, it maintains the previously selected options in memory.
18.2.5 Deleting the last alarms
Before deleting any alarms, make a note of the last alarm on the "Service Order" form.
•
Delete them after reading them, to check whether the alarms re-occur during the diagnostic cycle.
•
Delete them after repairing the appliance, to check whether they re-occur during testing.
5. Select diagnostics mode, turn the programme selector to the tenth position (alarm reading).
6. Press the START/PAUSE button and the nearest option button simultaneously (as shown in the
figure).
7. Hold down the buttons until the LEDs stop flashing and the LCD display shows "E00" (at least 5 seconds).
N.B. With this operation all the alarms stored are deleted.