System setup
What other functions can I change? (See page 16 for instructions.)
Function
0500
Filter Change
Reminder
The reminder
appears after
selected number of
days run time not
actual time.
0502
Furnace Filter for
Run Time
0520
UV Lamp
Replacement
0530
Adaptive Intelligent
Recovery
TM
See page 15 for
more information.
0540
Program Periods
0580
Compressor
Protection
0600
Heat Temperature
Range Stop
0610
Cool temperature
range stop
0615
Energy Saving
Heat Setpoint
0616
Energy Saving
Cooling Setpoint
0640
Clock Format
0650
Extended fan
timer (heat)
0660
Extended Fan
Timer (cool)
Settings & Options
0
Off (no reminder)
1
Reminder after 10-day run time (about 1 calendar month)
2
Reminder after 30-day run time (about 3 calendar months)
3
Reminder after 60-day run time (about 6 calendar months)
4
Reminder after 90-day run time (about 9 calendar months)
5
Reminder after 120-day run time (about 1 calendar year)
6
Reminder after 180-day run time (about 18 calendar months)
7
Reminder after 270-day run time (about 2 calendar years)
8
Reminder after 365-day run time (about 3 calendar years)
9
30 calendar days
10
60 calendar days
11
90 calendar days
12
120 calendar days
13
180 calendar days
14
365 calendar days
1
Counts both heat and cool
0
Counts cool only
0
Disabled
1
365 days
2
730 days
1
On
0
Off
4
4 program periods (Wake, Leave, Return, Sleep)
2
2 program periods (Wake, Sleep)
5
5-minute compressor off time
[Other options: 0, 1, 2, 3 or 4-minute off time)
90
Max. heat temperature setting is 90°F (32°C)
[Other options: 40-89°F (4°C to 32°C)]
50
Min. cool temperature setting is 50°F (10°C)
[Other options: 51-99°F (11°C to 37°C)]
65
65°F (18.5°C)
40-90°F (4.5°C to 32°C)
78
78°F (25.5°C)
50-99°F (10°C to 37°C)
12
12-hour clock (i.e., "3:30 pm")
24
24-hour clock (i.e., "15:30")
0
Off
90
Fan runs for 90 seconds after call for heat ends
[Other options: 30, 60, 120]
0
Off
90
Fan runs for 90 seconds after call for cooling ends
[Other options: 30, 60, 120]
19
33-00131ES—01