Installation Diagram Of Indoor And Outdoor Units; Optional Installation Parts - Toshiba RAS-B24B2KVG-E Installation Manual

Table of Contents

Advertisement

INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS

INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
Batteries
3
6
Flat head
wood screw
Remote control holder
2
Wireless remote control

Optional Installation Parts

Part
Parts name
code
Refrigerant piping
Liquid side : Ø6.35 mm
A
Gas side
: Ø12.70 mm
Pipe insulating material
B
(polyethylene foam, 8 mm thick)
Putty, PVC tapes
C
Refrigerant piping
must be protected
from physical
damage.
Install a plastic
cover or equivalent.
Vinyl tape
Apply after carrying
out a drainage test.
4
Q'ty
One
each
1
One
each
Hook
1
Installation
plate
Shield pipe
Saddle
Extension drain hose
(Not available, provided
by installer)
Fixing bolt arrangement of outdoor unit
• Secure the outdoor unit with fi xing bolts and nuts if the unit is likely to be
exposed to a strong wind.
• Use Ø8 mm or Ø10 mm anchor bolts and nuts.
90
w When using a multi-system outdoor unit, refer to the Installation Manual
provided with the model concerned.
2
For the rear left, bottom left and left piping
Wall
Cut out a piece of SPACER from
indoor unit packaging box, roll it and
insert between the indoor unit and wall to
tilt the indoor unit for better operation.
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Rear
right
Bottom
Rear
right
left
Bottom left
Do not allow the drain hose to get slack.
Cut the piping
hole sloped
slightly.
Make sure to run the drain hose sloped
downward.
Insulate the refrigerant pipes separately
with insulation, not together.
8 mm thick heat resisting
polyethylene foam
600
91 70
108
Drain outlet
Left

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-24b2avg-e