(9) Setting to factory setting status
The contents set of each scene file can be returned to the factory default status (preset status).
(1) Select a file to set to the factory default status by [FILE] button.
(2) If the color bar pattern or characters are displayed on the screen, press the [DISP] button to disable the
color bar pattern and character display. If the camera is in Freeze Mode, perform the cancellation
procedure (refer to the item "6.6 Freeze Operation") to return the camera to Live Image Mode.
(3) Push [MENU DOWN] and [DATA DOWN] buttons simultaneously for approx. 1 second.
(4) The preset operation starts. When the preset operation finishes, the character PRESET OK is displayed
for approx. 1 second.
7. 3 External Sync
j
When using the unit with an external sync signal, input VBS (composite video signal) or BS to EXT. SYNC
terminal on the rear panel, or input HD and VD to DC IN/SYNC terminal. When the external sync signal is
input, the camera automatically switches its sync from the internal sync to the external sync.
The operation is as shown below, depending on the unit's status and how external sync signals are input.
Unit's status
HD input
VD input
EXT. SYNC input
Operation
Shutter mode: EXT TRIG
EXT TRIG :1 PULSE SR
or 2PULSE
On
_
Off
Internal sync
On
-
Off
External sync with HD
(Only for H sync with HD)
Off
-
VBS
External sync with VBS
(H sync with HSYNC and SC
sync)
Off
_
SYNC
H sync with HSYNC
OR
|§|
VSSorSYNC
, j
Others
On
On
Off
External sync with HD, VD
(H-V sync with HD, VD)
Off
Off
VBS
External sync with VBS
(H-V sync and SC sync with
H SYNC, V SYNC)
Off
Off
SYNC
External sync with SYNC
(H-V sync with H SYNC, V
SYNC)
Off
On
Off
External sync with VD
(Only for VD reset)
On
Off
——
Off
Oft
On
Off
Oft
1
On
VBS or SYNC
ProNblted*l
Note: Don't use combination *1.
—: Don't care.
(1) External svnc signal input conditions
VBS, BS
: SYNC section
(75Q unbalanced)
Burst section
HD
: 2 to 5V (p-p)
VD
: 2 to 5V(p-p)
0.286±0.1V
0.286±0.1V
Negative
Negative
40