Show Commands; Table 36 Pcep Pcc Field Descriptions - Nokia 7705 SAR-W Series Manual

Service aggregation router, mpls
Table of Contents

Advertisement

MPLS Guide
4.9.2.2
Note: The following command outputs are examples only; actual displays may differ
depending on supported functionality and user configuration.
detail
Syntax
detail
Context
show>router>pcep>pcc
Description
This command displays PCEP PCC detailed information.
Output
The following output is an example of PCEP PCC detailed information, and
describes the fields.
Output Example
*A:Sar18 Dut-B>show>router>pcep# pcc detail
===============================================================================
Path Computation Element Protocol (PCEP) Path Computation Client (PCC) Info
===============================================================================
Admin Status
Unknown Msg Limit
Keepalive Interval
Capabilities List
Address
Report Path Constraints: True
Open Wait Timer
Sync Timer
Connection Timer
Max Sessions
===============================================================================
*A:Sar18 Dut-B>show>router>pcep#
Table 36
3HE 18686 AAAB TQZZA

Show Commands

PCEP PCC Field Descriptions
Label
Admin Status
Oper Status
Unknown Msg Limit
Keepalive Interval
DeadTimer Interval
Use subject to Terms available at: www.nokia.com
: Down
Oper Status
: 10 msg/min
: 50 seconds
DeadTimer Interval
: stateful-delegate stateful-pce rsvp-path
: 10.10.10.10
: 60 seconds
Keep Wait Timer
: 60 seconds
Request Timer
: 60 seconds
Allow Negotiations
: 1
Max Unknown Req
Description
The administrative status of the PCC
The operational status of the PCC
The maximum rate of unknown messages that can be
received on a PCEP session
The specified keepalive interval for the PCEP session
The specified dead time interval for the PCEP session
© 2022 Nokia.
PCEP
Table 36
: Down
: 150 seconds
: 60 seconds
: 120 seconds
: False
: 1000
359

Advertisement

Table of Contents
loading

Table of Contents