a
TO7VR [En}
Operation to reset
normal condition.
The microcomputer
may fall into malfunction
(impossibility to
operate, erroneous display, etc.) when the power cord is unplugged
while power is ON or due to an external factor. In this case, execute
the foltowing procedure to reset the microcomputer and return it to
1 Unplug the AC power plug from the wali outlet.
2 While holding the POWER switch depressed, plug the AC
|
plug into the power outlet.
i
Please
note that resetting the microcomputer
clears the contents
stored in and returns to the condition when .t left the factory
Amplifier
Symptom
Cause:
Remedy
Sound is not output or the volume level is
low.
eThe speaker cords are disconnected
@ MUTE is ON
(The MUTE ON indicator ts blinking}
@The SPEAKERS keys are set to OFF
@Tne TAPE 2 MONITOR key is set 10 ON
@ Connect them properly reterrng to "Connec-
—.6
tion of speakers"
@Press the MUTE key to OFF
@Set the SPEAKERS key to ON
e@Set the FAPE 2 MONITOR
key to OFF
Set
the input selector
to the position other than
tuner
32,
The STANDBY indicator blinks and sound is
not output.
Speaker cords are short-circuited
Turn the power off, eliminate the snort-circuit-
Ing, then turn on the power again
6
Sound is not output from one of the speak-
ers.
@ The speaker cord is disconnected
e@The
BALANCE
control
is set to an extreme
position
@ Connect tt properly referring to "Connection of
speakers"
®Adgjust the Left/Right balance
Sound
is not output
from
the surround
speaker and/or center speaker, or their sound
is very small.
@ The surround speaker cords and/or center speaker
cord are disconnected
.
@ The Surround play mode has not been engaged
@ The surround and center speaker levels are set to
the minimum
positions
Connect them properly referring to "Connec-
tion of speakers"
-
Adjust the surround and center speaker levels.
A hum noise is generated when the PHONO
input is selected.
@ The audio cord from the turntable 1s not inserted
securely into the PHONO jacks
e The turntable is not grounded
@insert the audio cord plugs securely
into_the
PHONO jacks
~~
@ Connect the grounding wire to the GND termi
nal on the rear panel
System control is not available when TAPE1
or MD is selected.
@"TAPE1"
of "MD" is not displayed
e Switch the display to TAPE 1 or MD. _
= 12 ~ 16,
System control is not available.
@ Tne XS8 and SL16 modes were switched while
the AC plug 's left plugged into the wall power
outlet
@ Unplug the AC plug from the wall outlet and
switch tne XS8 or SL16 mode as required.
Display is dimly tit.
@ The setting 1s not correct
# Adjust the brightness with the DISPLAY key
-
8.
Tuner
Symptom
Cause
Remedy:
Radio stations cannot be received.
@ No antenna :s connected
e The broadcast band is not set properly
@ The frequency
of the desired station is not tuned
@ Connect an antenna
eSet the broadcast band properly.
i
Tune
the frequency of the desired station _
wd
interference.
@ Noise gue to ignition noise of an automobile
@ Norse due to an infiuence from an electric appl
ance
e@ Noise due to a nearby TV set
e@install the outdoor
antenna
away
trom
the
road
e Turn off the power to the appliance
einstall the system
farther away
from
the TV
set
A station which was preset cannot
be re-
ceived by pressing the corresponding
nu-
meric key.
e The preset station belongs to a frequency that
cannot be received
eThe
preset
memory
was
cleared
because
the
cower cord had been unplugged for a long period
of time
e@ Tne TUNER input is not delected
@ Preset a station with a receivable frequency
= _i8
e Preset the station again
Select the TUNER input