HP Jet Fusion 340 Product Documentation Site Preparation Manual page 22

Hide thumbs Also See for Jet Fusion 340:
Table of Contents

Advertisement

5.
Attach the power cable to the plate, install a strain relief to the plate, and make sure the PE conductor
extends a minimum of 203 mm (8 in) from the grommet or strain relief.
6.
Apply a ferrule to the PE wire; the electrician must provide the correct ferrule.
7.
Install two jumpers HP PN 0360-3729 in the terminal blocks as shown in the picture, and tighten four flat-
head screws.
8.
Connect the two line wires to the terminal block and connect the ground cable to the PE terminal block.
Tighten three flat-head screws.
18
Chapter 4 Plan the printer production area and environment
or
ENWW

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jet fusion 540Jet fusion 580

Table of Contents