MULTI V Water IV
7. Capacity tables
Inlet Water
Combination
(%)
Temp. ( )
60
45
10
15
20
25
50
30
35
40
45
Note
1. TC: Total Capacity(kW), PI : Power Input(kW, Comp. + Outdoor fan motor)
2. Capacity tables show the average value of conditions which may occur.
3. By applying the Variable Water Flow Valve Control KIT, the minimum flow rate to 40% is applied. Refer to the Gray colored range.
94
Heat Pump
Water Flow
20
Rate
14
[ /min]
TC
PI
TC
169.2
57.6
12.48
62.5
211.5
57.6
12.24
62.5
423.0
57.6
11.31
62.5
528.8
57.6
10.95
62.5
634.5
57.6
10.77
62.5
169.2
48.0
2.44
52.0
211.5
48.0
2.39
52.0
423.0
48.0
2.17
52.0
528.8
48.0
2.12
52.0
634.5
48.0
2.09
52.0
169.2
48.0
3.31
52.0
211.5
48.0
3.24
52.0
423.0
48.0
2.98
52.0
528.8
48.0
2.89
52.0
634.5
48.0
2.85
52.0
169.2
48.0
4.09
52.0
211.5
48.0
4.01
52.0
423.0
48.0
3.69
52.0
528.8
48.0
3.58
52.0
634.5
48.0
3.52
52.0
169.2
48.0
4.98
52.0
211.5
48.0
4.88
52.0
423.0
48.0
4.49
52.0
528.8
48.0
4.36
52.0
634.5
48.0
4.28
52.0
169.2
48.0
6.15
52.0
211.5
48.0
6.02
52.0
423.0
48.0
5.52
52.0
528.8
48.0
5.39
52.0
634.5
48.0
5.31
52.0
169.2
48.0
6.82
52.0
211.5
48.0
6.68
52.0
423.0
48.0
6.16
52.0
528.8
48.0
5.98
52.0
634.5
48.0
5.91
52.0
169.2
48.0
8.10
52.0
211.5
48.0
7.92
52.0
423.0
48.0
7.28
52.0
528.8
48.0
7.07
52.0
634.5
48.0
6.97
52.0
169.2
48.0
9.37
52.0
211.5
48.0
9.18
52.0
423.0
48.0
8.40
52.0
528.8
48.0
8.15
52.0
634.5
48.0
8.03
52.0
Indoor Air Temp. (DB/WB,
23
26
27
16
18
19
PI
TC
PI
TC
14.51
67.9
16.94
73.9
19.09
14.29
67.9
16.68
73.9
18.77
13.40
67.9
15.60
73.9
17.51
13.09
67.9
15.29
73.9
17.17
12.94
67.9
15.13
73.9
17.00
2.81
56.7
3.35
61.6
3.70
2.78
56.7
3.29
61.6
3.64
2.61
56.7
3.07
61.6
3.45
2.61
56.7
3.00
61.6
3.36
2.61
56.7
2.95
61.6
3.31
3.85
56.7
4.51
61.6
5.04
3.79
56.7
4.43
61.6
4.96
3.54
56.7
4.14
61.6
4.65
3.49
56.7
4.05
61.6
4.56
3.46
56.7
4.02
61.6
4.51
4.78
56.7
5.52
61.6
6.23
4.69
56.7
5.44
61.6
6.13
4.36
56.7
5.09
61.6
5.73
4.27
56.7
4.99
61.6
5.64
4.23
56.7
4.95
61.6
5.59
5.78
56.7
6.74
61.6
7.62
5.69
56.7
6.64
61.6
7.49
5.34
56.7
6.21
61.6
6.98
5.21
56.7
6.08
61.6
6.86
5.15
56.7
6.02
61.6
6.79
7.15
56.7
8.33
61.6
9.37
7.02
56.7
8.18
61.6
9.22
6.55
56.7
7.64
61.6
8.62
6.41
56.7
7.49
61.6
8.44
6.35
56.7
7.43
61.6
8.36
7.92
56.7
9.24
61.6
10.39
7.80
56.7
9.09
61.6
10.21
7.29
56.7
8.49
61.6
9.57
7.15
56.7
8.31
61.6
9.39
7.08
56.7
8.23
61.6
9.30
9.38
56.7
10.95
61.6
12.31
9.23
56.7
10.76
61.6
12.11
8.63
56.7
10.05
61.6
11.33
8.44
56.7
9.86
61.6
11.12
8.35
56.7
9.76
61.6
11.00
10.83
56.7
12.65
61.6
14.24
10.66
56.7
12.45
61.6
14.00
9.96
56.7
11.61
61.6
13.09
9.74
56.7
11.41
61.6
12.84
9.64
56.7
11.31
61.6
12.71
Cooling Capacity (44 HP)
)
28
30
20
22
PI
TC
PI
TC
PI
76.1
19.53
79.2
19.96
76.1
19.21
79.2
19.65
76.1
17.97
79.2
18.43
76.1
17.62
79.2
18.07
76.1
17.44
79.2
17.89
63.4
3.79
66.0
3.91
63.4
3.75
66.0
3.84
63.4
3.56
66.0
3.56
63.4
3.41
66.0
3.53
63.4
3.33
66.0
3.51
63.4
5.17
66.0
5.30
63.4
5.09
66.0
5.21
63.4
4.78
66.0
4.88
63.4
4.65
66.0
4.79
63.4
4.60
66.0
4.75
63.4
6.39
66.0
6.53
63.4
6.29
66.0
6.42
63.4
5.87
66.0
6.03
63.4
5.77
66.0
5.91
63.4
5.72
66.0
5.85
63.4
7.80
66.0
7.97
63.4
7.67
66.0
7.84
63.4
7.16
66.0
7.34
63.4
7.02
66.0
7.20
63.4
6.96
66.0
7.13
63.4
9.60
66.0
9.81
63.4
9.43
66.0
9.66
63.4
8.79
66.0
9.05
63.4
8.66
66.0
8.87
63.4
8.58
66.0
8.78
63.4
10.65
66.0
10.90
63.4
10.47
66.0
10.72
63.4
9.78
66.0
10.04
63.4
9.61
66.0
9.86
63.4
9.52
66.0
9.77
63.4
12.61
66.0
12.91
63.4
12.41
66.0
12.70
63.4
11.60
66.0
11.90
63.4
11.38
66.0
11.67
63.4
11.27
66.0
11.56
63.4
14.57
66.0
14.92
63.4
14.34
66.0
14.69
63.4
13.41
66.0
13.75
63.4
13.15
66.0
13.47
63.4
13.02
66.0
13.35
Outside Units
32
24
TC
PI
81.4
20.40
81.4
20.08
81.4
18.77
81.4
18.25
81.4
18.00
67.8
3.97
67.8
3.91
67.8
3.64
67.8
3.54
67.8
3.49
67.8
5.40
67.8
5.31
67.8
4.96
67.8
4.84
67.8
4.77
67.8
6.65
67.8
6.55
67.8
6.13
67.8
5.98
67.8
5.92
67.8
8.10
67.8
7.97
67.8
7.49
67.8
7.29
67.8
7.18
67.8
9.99
67.8
9.82
67.8
9.18
67.8
8.96
67.8
8.86
67.8
11.08
67.8
10.91
67.8
10.21
67.8
9.95
67.8
9.82
67.8
13.14
67.8
12.94
67.8
12.10
67.8
11.77
67.8
11.60
67.8
15.20
67.8
14.95
67.8
13.98
67.8
13.59
67.8
13.39