QWIK-PURE
®
WARNING
WARNING
10.2 Maintenance schedule
Maintenance
Turbidity test of wastewater and documenting the
result
Replace filter cartridges
Replacing solenoid valves
Replace piston
Clean assembly units
Visual inspection
Leakage test
82 | 124
Insufficient qualification!
Insufficient qualification of the personnel carrying out work on the product and
accessories can lead to accidents, personal injury and damage to property as well as
impair operation.
•
All work on the product and the accessories may only be carried out by skilled
technical personnel - customer service.
Ingress of moisture or foreign bodies!
Water and foreign objects can get into the opened FRC control unit or into the
opened electrical connections if electrical connections are disconnected or if
the FRC control unit is opened. Ingress of water or foreign bodies can lead to
accidents, personal injury and damage to property as well as impairments in
operation.
•
Protect the FRC control unit and the electrical connections from splash water
and moisture.
•
Open the FRC control unit and disconnect the electrical connections in a dry
location only.
•
Do not insert any foreign objects into the openings of the FRC control unit.
•
Keep all contact surfaces and openings free of dirt and moisture.
Installation and operation manual
Interval
•
Weekly
•
Mandatory in case of a negative result of the
turbidity test
•
Maximum lifetime of the filter cartridges
reached, see section "9.2.3 Querying filter
cartridge status"
•
At least annually
•
Maximum lifetime of the solenoid valves, see
section "9.2.4 Querying the solenoid valve
status"
•
Maximum lifetime of the piston reached, see
section "9.2.5 Querying piston status"
•
As part of troubleshooting
•
Weekly
•
Recommendation: After all assembly and
maintenance work on the product