Format Of Possible Cabling Exception Messages; Cabling Example 1; Cabling Suggested Action 1; Cabling Example 2 - HP 3PAR StoreServ 7000 Troubleshooting Manual

Hide thumbs Also See for 3PAR StoreServ 7000:
Table of Contents

Advertisement

Format of Possible cabling Exception Messages

Cabling <cageID> "Cabled to <nodelist>, remove a cable from <nodelist>"
Cabling <nodeID> "No cabling data for <nodeID>. Check status of <nodeID>"
Cabling <cageID> "Cage is connected to too many node ports (<portlist>)"
Cabling <cageID> "Cage has multiple paths to <portlist>, correct cabling"
Cabling <cageID> "I/O <moduleID> missing.
Cabling <cageID> "Cage not connected to <nodeID>, move one connection from <nodeID> to <nodeID>"
Cabling <cageID> "Cage connected to different ports <node&portID> and <node&portID>"
Cabling <cageID> "Cage connected to non-paired nodes <node&portID> and <node&portID>"
Cabling <cageID> "Check connections or replace cable from (<cage,module,portID>) to (<cage,module,portID>) - failed links"
Cabling <cageID> "Check connections or replace cable from (<cage,module,portID>) to (<cage,module,portID>) - links at
<speed>"
Cabling <nodepairID> "<node&portID> has <count> cages, <node&portID> has <count> cages"
Cabling <cageID> "Cable in (<cage,module,portID>) should be in (<cage,module,portID>)"
Cabling <cageID> "No PDs installed in cage, cabling check incomplete"
Cabling <cageID> "<node&portID> has <count> cages connected, Maximum is <count> (<cagelist>)"
Cabling <cageID> "<node&portID> should be cabled in the order: (<cagelist>)"

cabling Example 1

Component -Summary Description- Qty
Cabling
Bad SAS connection
Component -Identifier- ----------------------------------------Detailed Description-----------------------------------------
Cabling
cage7
6Gbps

cabling Suggested Action 1

Use the CLI showcage command to verify that both cages are available through two ports, before
replacing the cable specified in the error message.
cli% cli% showcage cage6 cage7
Id Name
LoopA Pos.A LoopB Pos.B Drives Temp
6 cage6 3:0:4
7 cage7 3:0:4

cabling Example 2

Cabling
checkhealth -detail cabling
Checking cabling
Component --Summary Description--- Qty
Cabling
Wrong I/O module or port
--------------------------------------
1 total
Component -Identifier- ---------------------Detailed Description----------------------
Cabling
cage2
Cabling
cage2
--------------------------------------------------------------------------------------
2 total
root@jnodec103288:~# showcage cage2
Id Name
LoopA Pos.A LoopB Pos.B Drives Temp
2 cage2 1:0:2

cabling Suggested Action 2

For cables that should be moved to different ports in the same I/O module: Use the CLI showcage
command to verify that the cage is available through two ports, before moving the cable(s) to the
specified ports. For cables that should be moved between different I/O modules and/or cages,
contact HP support to request support for changing the cabling of your system. See
HP Support about System Setup" (page
degraded PDs and LDs.
cli% showcage cage2
Id Name
LoopA Pos.A LoopB Pos.B Drives Temp
2 cage2 1:0:2
38
Troubleshooting
Check status and cabling to <cageID> I/O <moduleID>"
1
Check connections or replace cable from (cage6, I/O 0, DP-2) to (cage7, I/O 0, DP-1) - links at
1 2:0:4
0
0 2:0:4
1
2
2
Cable in (cage2, I/O 0, DP-2) should be in (cage2, I/O 0, DP-1)
Cable in (cage2, I/O 0, DP-1) should be in (cage2, I/O 0, DP-2)
1 0:0:2
0
10 13-34 402e 402e DCS1
73). Moving cables on a running system can cause
1 0:0:2
0
RevA RevB Model FormFactor
10 28-30 1.76 1.76 DCS4
10 27-30 1.76 1.76 DCS4
RevA RevB Model FormFactor
LFF
RevA RevB Model FormFactor
10 13-34 402e 402e DCS1
SFF
SFF