Selection of the operating point in fixed command value mode
The selection of the operating point for p and n can be specified cyclically via the
parameters. The function is selected in the 1-ms task. For pressure, the operating
point can be selected using P-0-1394, while the operating point for speed can be
selected using P-0-1395. The assignment to the operating point is provided in the
following table:
Table 47: Selection of the operating point
Value for the selection of the operating point
P-0-1394/P-0-1395
0
1
2
3
ELSE
The operating points for pressure p and speed n can be configured in the
following parameters:
Table 48: Configuration of the operating points
Operating point index
0
1
2
3
3. Configuration of the hydraulic power unit (HPU)
The configuration of the HPU is pre-set at the factory and usually does not need to
be adjusted. Any changes that are necessary nonetheless can be made via parameter
P-0-1380. Moreover, the threshold values can be adjusted, if necessary.
Only carry out changes if they are absolutely necessary and you have agreed them
with Bosch Rexroth.
Commissioning 93/128
Operating point
No new operating point is assigned. The last
valid value in the command value presetting
remains active.
Operating point
Pressure p
P-0-1311[100]
P-0-1311[101]
P-0-1311[102]
P-0-1311[103]
CytroBox, RE 51057-B/11.19, Bosch Rexroth AG
0
1
2
3
Speed n
P-0-1311[110]
P-0-1311[111]
P-0-1311[112]
P-0-1311[113]