Speed Band Output - Toshiba G3 Workbook

Applications workbook
Table of Contents

Advertisement

Introduction
A G3's output contacts can be programmed to change state based upon its output frequency. In the following
example, the customer's system will see a short when the output frequency is between 40 and 50 Hz and an
open when at any other speed.
Connections
ST
LOW A
To customer
This works in either panel or remote mode. In remote, remember to include a direction reference
Programming
Group
UTILITY PARAMETERS
UTILITY PARAMETERS
TERMINAL SELECTION PARAMETERS
TERMINAL SELECTION PARAMETERS
TERMINAL SELECTION PARAMETERS
TERMINAL SELECTION PARAMETERS
TERMINAL SELECTION PARAMETERS
* change to adjust frequency band
For additional assistance, please contact Toshiba Adjustable Speed Drive Marketing Dept. at (800) 872-

Speed Band Output

TERMINAL STRIP
CC
LOW C
RCH A
RCH B
To customer
Parameter
Blind Function Selection
Terminal Selection Params Blind
"Low" Contacts Function
Low Speed Signal Output Freq
"Rch" Contacts Function
Speed Reach Maximum Frequency
Speed Reach Minimum Frequency
2192
11
.
Value
1
1
4
*40
9
*50
*50
25

Advertisement

Table of Contents
loading

Table of Contents