Table 8-3
Contents of revision of SPARC M10-4/M10-4S Service Manual
Section number or name
1.3
4.3
7.4.4
7.5.1
7.5.2
24.2.1
24.3.1
24.4
24.5
25.3.1
25.3.2
25.4
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2043 ・ October 2013
90
Contents of revision
The certification standards on the standard label described in "1.3 Labels/Tags" will
be changed to the following:
SPARC M10-4/M10-4S
Safety: NRTL/C
Radio wave: VCCI-A, FCC-A, DOC-A, KCC, and C-Tick
Safety and radio wave: CE, BSMI, and GOST-R
Crossbar box
Safety: NRTL/C
Radio wave: VCCI-A, FCC-A, DOC-A, KCC, and C-Tick
Safety and radio wave: CE and CU
"Inactive/hot" for "Crossbar cable (electrical)" and "Crossbar cable (optical)"
described in "Table 4-8 Types of maintenance for cables" in "4.3 Understanding
Types of Maintenance" is changed to "Unavailable."
Some procedures in "7.4.4 Removing PCI Express cable" will be described differently
for each model. For details, see
Some procedures in "7.5.1 Attaching PCI Express cable" will be described differently
for each model. For details, see
Step 4 in "7.5.2 Installing CPU memory unit upper" will be changed.
For details, see
"Installing CPU memory unit
"Inactive/hot" described in "Table 24-1 Types of maintenance for crossbar cable
(electrical)" in "24.2.1 Types of maintenance" is changed to "Unavailable."
"24.3.1 Inactive/hot maintenance" is deleted.
Steps 1 and 2 in "24.4 Removing crossbar cable (electrical)" will be changed. For
details, see
"Removing Crossbar Cable
Steps 1 and 2 in "24.5 Attaching crossbar cable (electrical)" will be changed as
follows.
1. Write down corresponding connection destinations of connectors 1 and 2
respectively for new crossbar cables (electrical) to replace, on the connection
destination indication labels attached to the building block expansion kit #1,
and attach them to the crossbar cables (electrical). In addition, select
corresponding labels from color indication labels similarly attached, and
attach them next to the labels indicating the connection destinations.
2. Connect two crossbar cables (electrical) to each cabinet.
Hold the connector part of the crossbar cable (electrical) and insert it straight into
the opening. Do not hold the cable part when inserting the cable.
Step 5 described in "25.3.1 Inactive/cold maintenance" and "25.3.2 System-stopped
maintenance" is changed as follows.
5. Remove all power cords from the power supply unit of the maintenance-target
SPARC M10-4S.
The following note is added in "25.4 Removing Crossbar Cable (Optical)."
Note - There is no problem if you remove the crossbar cables at the crossbar box side
when electricity is supplied.
Steps 1 and 2 will be changed. For details, see
"Removing PCI Express
cable."
"Installing PCI Express
cable."
upper."
(Electrical)."
"Removing Crossbar Cable
(Optical)."