Sharp UP-3300 Service Manual page 18

Pos terminal
Hide thumbs Also See for UP-3300:
Table of Contents

Advertisement

4.
4.1 UP-3300 IPL
No
Procedure on P.C. side
1
Install "UTL33.EXE" on the P.C.
6
Connect P.C. and UP-3300 via IR. (Fig 1)
7
Execute "UTL33.EXE" on P.C.
Operation:
>UTL33 3300_1.ROM 3300_2.ROM
("3300_1.ROM" and "3300_2.ROM" are file name of S-type
ROM object.)
8
Program data is sent to UP-3300 automatically.
9
"UTL33.EXE" is completed.
P.C. shows
"Completed."
No
Procedure on UP-3300 side
2
Turn OFF the power.
3
Select "IPL Mode".
Set "IPL Switch" of UP-3300 to "ON".
IPL SW
ON
IR Filter
4
Turn ON the power.
5
Starting of "IPL Mode".
UP-3300 shows
"IPL from IR"
IPL from IR
8
Program data is received from P.C. automatically.
UP-3300 shows
IPL from IR
Connected IRDA 115200
21 22 23 24 25 26 27 28
9
UP-3300 shows
"Completed."
IPL from IR
Connected IRDA 115200
21 22 23 24 25 26 27 28
29 2A 2B 2C 2D 2E 2F
Completed.
IPL from IR
Connected IRDA 115200
30 31 32 33 34 35 36 37
38 39 3A 3B 3C 3D 3E 3F
Completed.
10
Turn OFF the power.
11
Select "Normal Mode".
Set "IPL switch" to "OFF".
12
Execute "Service Reset" on UP-3300.
3 – 4