00825-0600-4410, Rev BB
July 2022
Emerson Wireless 1410S Gateway

Advertisement

loading

Summary of Contents for Emerson 1410S

  • Page 1 Quick Start Guide 00825-0600-4410, Rev BB July 2022 Emerson Wireless 1410S Gateway...
  • Page 2 Voir les instructions. Repair/maintenance The Emerson Wireless 1410S Gateway contains no user serviceable components. If the device is not functioning properly, see the troubleshooting guide in the Emerson Wireless 1410S Gateway manual. If these troubleshooting steps do not resolve the problem, contact the factory.
  • Page 3: Table Of Contents

    July 2022 Quick Start Guide CAUTION Equipment conformance Protection may be impaired if the device is used in a manner not specified by the manufacturer. NOTICE The 1410S1 needs an external IP54 that meets the requirements of CAN/CSA 60079-0. Le 1410S1 a besoin d'un IP54 externe qui répond aux exigences de CAN/CSA 60079-0. Contents Wireless planning.........................
  • Page 4 Quick Start Guide July 2022 Emerson.com...
  • Page 5: Wireless Planning

    This will result in a simpler and faster network installation. Gateway redundancy If the wireless gateway was ordered with redundancy (Gateway Redundancy code RD), refer to Appendix D in the Emerson Wireless 1420 Gateway Reference Manual for additional installation instructions. Gateway firmware compatability The gateway firmware needs to be compatible with host connections being made.
  • Page 6: Pc Requirements

    Configuration of the gateway is done through a secure web interface. Recent versions of the following browsers are supported: ™ • Chrome browser ® • Mozilla Firefox • Microsoft Edge Hard disk space • AMS Wireless Configurator: 1.5 GB • Gateway Setup CD: 250 MB Emerson.com...
  • Page 7: Initial Connection And Configuration

    Powering the Gateway For the Emerson Wireless 1410S Gateway, bench top power will be needed to power the Gateway by wiring a 10.5–30 VDC power source. An Emerson Wireless 1410S Gateway can also be powered via Power over Ethernet (PoE) and is compliant with the IEEE 802.3af standard.
  • Page 8 D. Ethernet port 1. When this port is activated, the factory IP address is 192.168.1.10. E. Ethernet port 2. When this port is activated, the factory IP address is 192.168.2.10. F. Emerson 1410S power and serial connections G. 781S power terminals H. 781S data terminals I. 10.5 to 30 VDC power input J.
  • Page 9 Installer to ensure external conduit/cable fittings are Type 4X rated or better (C22.2 No 94.2/UL 50E requirement). Emerson Wireless 1410S2 Gateway hardware revision 1.0.0 configured with Intrinsically Safe Outputs option “A” can only be powered by 24 VDC power source.
  • Page 10 DeltaV Ready Gateway. Windows 10 Procedure 1. Select the network icon in the lower right corner of the Windows 10 workspace. 2. Select the Network & Internet Settings link. Figure 3-3: WiFi Connections Menu Emerson.com...
  • Page 11 July 2022 Quick Start Guide 3. Select Change adapter options. Figure 3-4: Network & Internet Settings 4. Right click the network interface connection that the gateway is plugged into, and select Properties. Quick Start Guide...
  • Page 12 5. Select Internet Protocol Version 4 (TCP/IPv4) → Properties. Figure 3-5: Ethernet properties Note If the PC/laptop is from another network, record the current IP address and other settings so the PC/laptop can be returned to the original network after the gateway has been configured. Emerson.com...
  • Page 13 July 2022 Quick Start Guide 6. Select the Use the following IP address button. Figure 3-6: IP Address Properties 7. In the IP Address field, enter 192.168.1.11. 8. In the Subnet mask field, enter 255.255.255.0. 9. Select OK for both the Internet Protocol (TCP/IP) Properties window and the Local Area Connection Properties window.
  • Page 14 This procedure may be necessary when using a Chrome browser with Windows operating systems. Procedure 1. Open web browser. 2. Navigate to Settings → Advanced. 3. In the System section, click Open proxy settings. Example Figure 3-7: Proxy settings menu. Only use if a proxy is needed. Emerson.com...
  • Page 15 July 2022 Quick Start Guide Configure the Gateway To complete initial configuration for the gateway, follow the steps below. This will have to be done be done for both networks. Procedure 1. Access the default web page for the gateway at https:// 192.168.1.10.
  • Page 16 1. Navigate to System Settings → Users → User Accounts to change passwords and add users with the following steps. a) For DeltaV Ready Gateways, access gateway web interface from DeltaV Explorer 2. Change admin, operator, maintenance, and executive passwords to a secure password that adheres to user’s password requirements. Emerson.com...
  • Page 17 July 2022 Quick Start Guide Figure 3-10: Navigating to User Accounts page NOTICE Changing passwords is HIGHLY SUGGESTED before installing the gateway for full use. WARNING There is no way to recover lost passwords. The only way to access a gateway that no longer has known credentials is to factory reset the gateway.
  • Page 18: Physical Installation

    Find a location where the gateway has convenient access to the host system network (process control network). 4.1.1 1401S1 DIN-rail mounting The Emerson Wireless 1410S1 Gateway can be snapped onto a DIN TS35/7.5 or TS35/15 rail system. To clip the gateway onto the DIN rail, see Figure 4-1.
  • Page 19 July 2022 Quick Start Guide Figure 4-1: Emerson 1410S1 Mounting Quick Start Guide...
  • Page 20 2. Use a 1/2-in. wrench to fasten the nuts to the u-bolt. 3. Repeat for the second u-bolt and the lower mounting holes. Figure 4-2: Emerson 1410S2 Mounting 4.1.3 1410S2 Surface mount...
  • Page 21 July 2022 Quick Start Guide Mount the gateway using the following procedure: Procedure Install gateway into surface as shown in Figure 4-3. Screws shown as example. Figure 4-3: Emerson 1410S2 Surface Mounting Quick Start Guide...
  • Page 22 Belden 3084A. Recommended cable specifications are an ambient temperature rating of at least 100°C and 18-24 AWG. Maximum cable length between 1410S and 781S is 400 m (1312 ft) using these cable specs. Procedure 1.
  • Page 23 July 2022 Quick Start Guide Note 781S shield must be connected at gateway. Figure 4-4: Emerson 1410S1 Wiring diagram with 781S smart antenna A. Emerson Wireless 1410S1 Gateway B. Terminal connections C. Shielded, twisted pair cable D. Emerson Wireless 781S Smart Antenna E.
  • Page 24 Quick Start Guide July 2022 Figure 4-5: Emerson 1410S2 Wiring Diagram with 781S Smart Antenna A. Emerson Wireless 1410S2 Gateway B. Terminal connections C. Shielded, twisted pair cable D. Emerson Wireless 781S Smart Antenna E. 781S power terminals F. 781S data terminals G.
  • Page 25 Emerson 1410S grounding 4.3.1 Emerson 1410S1 grounding The Emerson Wireless 1410S1 Gateway is grounded through the DIN-rail mounting plate on the back of the gateway. The DIN-rail should always be grounded in accordance with national and local electrical codes. Ensure proper contact between gateway's mounting plate and DIN-rail for grounding.
  • Page 26 July 2022 4.6.1 Security best practices For security best practices, please see Emerson Wireless Security Whitepaper. User is solely responsible for the security of their system and products installed on such systems. These recommendations are in addition to user’s product and cybersecurity policies.
  • Page 27: Software Installation (Optional)

    July 2022 Quick Start Guide Software installation (optional) Install Security Setup Utility (only required for secure host connections or OPC-DA communications) and AMS Wireless Configurator as needed. See Reference Manual for further information. The gateway firmware needs to be compatible with host connections being made.
  • Page 28: Verify Operations

    ID and Join Key that can be found on the gateway’s Network Settings Page. 2. Verify field devices are joined to the network and displayed on the Devices page of the gateway web interface. 3. Verify host system is receiving field device data. Emerson.com...
  • Page 29: Product Certifications

    European Directive Information A copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EU Declaration of Conformity can be found at Emerson.com. 7.1.2 Ordinary location certification...
  • Page 30 CAN / CSA 60079-7:2016 et 6.3.13 de CAN / CSA 60079-11:2014. Ceci doit être pris en compte lors de l'installation. 3. The 1410S1 needs an external IP54 that meets the requirements of CAN/CSA 60079-0. Le 1410S1 a besoin d'un IP54 externe qui répond aux exigences de CAN/CSA 60079-0. Emerson.com...
  • Page 31 European Directive Information A copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EU Declaration of Conformity can be found at Emerson.com. 7.2.2 Ordinary location certification...
  • Page 32 Avertissement: L'équipement n'est pas capable de résister au test de résistance électrique de 500V tel que défini dans la clause 6.1 de CAN / CSA 60079-7: 2016 et 6.3.13 de CAN / CSA 60079-11: 2014. Ceci doit être pris en compte lors de l'installation. Emerson.com...
  • Page 33 July 2022 Quick Start Guide 7.2.6 Europe N1 ATEX Increased Safety with Intrinsically Safe Outputs to Zone 0 Certificate SGS20ATEX0036X Markings II 3(1)G Ex ec [ia Ga] IIC T4 Gc (-40 °C ≤ T ≤ +65 °C) Standards EN IEC 60079-0: 2018, EN IEC 60079-7:2015+A1:2018, EN 60079-11: 2012, EN 60079-15:2010, EN 60079-31:2014 N1 ATEX Increased Safety with Intrinsically Safe Outputs to Zone 0 (For use only with the Cisco Outdoor Access Point Model IW-6300H-AC-x-K9)
  • Page 34 ND ATEX Dust-Ignition Proof with Intrinsically Safe Outputs to Zone 2 Certificate SGS20ATEX0036X Markings II 3D (3G) Ex tc [ic IIC Gc] IIIC T90 °C Dc (-40 °C ≤ T ≤ +65 °C) Standards EN IEC 60079-0: 2018, EN IEC 60079-7:2015+A1:2018, EN 60079-11: 2012, EN 60079-15:2010, EN 60079-31:2014 Emerson.com...
  • Page 35 July 2022 Quick Start Guide Special Conditions for Safe Use (X): 1. The enclosure’s polyurethane paint finish may constitute an electrostatic hazard. Care should be taken to protect it from external conditions conducive to the build-up of electrostatic charge on such surfaces.
  • Page 36 1. The enclosure’s polyurethane paint finish may constitute an electrostatic hazard. Care should be taken to protect it from external conditions conducive to the build-up of electrostatic charge on such surfaces. The equipment must only be cleaned with a damp cloth. Emerson.com...
  • Page 37 July 2022 Quick Start Guide 2. The equipment is not capable of withstanding the 500V electrical strength test as defined in clause 6.1 of IEC 60079-7:2015+ A1:2017. This must be taken into account during installation. NF IECEx Dust-Ignition Proof with Intrinsically Safe Outputs to Zone 2 Certificate IECEx BAS.20.
  • Page 38 Quick Start Guide July 2022 7.2.8 Declaration of Conformity Emerson.com...
  • Page 39 July 2022 Quick Start Guide Quick Start Guide...
  • Page 40 Quick Start Guide July 2022 Emerson.com...
  • Page 41 July 2022 Quick Start Guide Quick Start Guide...
  • Page 42 Quick Start Guide July 2022 Emerson.com...
  • Page 43 July 2022 Quick Start Guide Quick Start Guide...
  • Page 44 For more information: Emerson.com © 2022 Emerson. All rights reserved. Emerson Terms and Conditions of Sale are available upon request. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount is a mark of one of the Emerson family of companies.