Toshiba G3+ PACK Operation Manual Addendum page 17

Asd, 480 volt ratings
Hide thumbs Also See for G3+ PACK:
Table of Contents

Advertisement

Parameter
Upper/Lower Limit
Frequency Jump
O
PERATING
Edit Function
F
UNCTIONS
Blind Function
User-defined Defaults
Interface
Fault Display
D
ISPLAY
Monitor Functions
Selectable Units Display
LED Charge Indicator
LED Local/Remote Indicator
Protective Functions
ASD/M
OTOR
Electronic Thermal
Characteristics
Reset
Ridethrough Control
G3+ Pack Addendum
Item Name
Limits the frequency between set values (0 to max. frequency). Can be
indicated via output contactor.
Three Jump frequency settings; each with unique band settings.
Easy-access user group containing all changed parameters.
Select to display parameter groups and parameters.
User-set parameters can be saved into a default library. User may then
default drive to Toshiba's factory settings or the user-stored settings.
Two-line backlit display, LCD 20 characters per line.
Overcurrent, overvoltage, heatsink overheat, load-side short-circuit,
load-side ground fault, ASD overload, stator overcurrent during start-up,
load-side overcurrent during start-up, EEPROM error, RAM error, ROM
error, communication error, dynamic braking unit overcurrent/
overload, emergency stop, undervoltage, low current, overtorque,
open output phase, motor overload.
Bolded items may be selected or deselected.
Terminal input/output status, forward/reverse, frequency setting value,
output frequency, output current, output voltage, input power, output
power, torque current, cumulative run time, past faults, excitation
current, DBR overload ratio, ASD overload ratio, motor overload ratio,
PID feedback value, DC voltage.
Scales the frequency display.
Displays current as amps or % and voltage as V or %.
Indicates that the main circuit capacitors are charged (On) or discharged
(Off).
Mounted at the Local/Remote key. Indicates Local (On) or Remote
control (Off).
Soft-stall, current limit, overcurrent, overvoltage, short-circuit at load,
load-side ground fault, undervoltage, momentary power failure,
regeneration power ridethrough, electronic thermal overload protection,
main circuit overcurrent at start-up, load-side overcurrent during start-
up, DBR resistor overcurrent/overload, heatsink over heat, emergency
stop, open output phase.
The motor overload protection setting at the ASD may be adjusted for
the motor rated amperage. The motor overload setting has a speed-
sensitivity adjustment, Soft stall feature, and the motor 150% run time is
programmable.
Fault reset via keypad, remote contact closure, or programming drive
retry. Cycling power also resets fault (fault display can be maintained).
The G3+ Pack may be configured to use regenerative energy from the
motor to maintain programmable settings during a brownout.