12-3 Pressure & Capacity mark································································································ · · · ··························· 12-3 12-4 Q & A for Non-trouble··································································································· · · · ······························· 12-4 12-5 Cleaning /Filter Change································································································· · · · ····························· 12-7 12-6 Installation············································································································ · · · ············································ 12-9 12-7 Installation Diagram of Indoor Unit and Outdoor Unit···································································· 12-10 Samsung Electronics...
Page 5
Never store or load the air conditioner upside down or sideways to prevent the damage to the compressor. Young children or in rm persons should be always supervised when they use the air conditioner. Max current is measured according to IEC standard for safety. Current is measured according to ISO standard for energy e ciency. Samsung Electronics...
Page 6
On those hot sweltering summer days and long restless nights, there is no better escape from the heat than the cool comforts of home. Your new air conditioner brings an end to exhausting hot summer days and lets you rest. Beat the heat with your own air conditioner this summer. Your new air conditioner not only provides maximum cooling power in the summer, but also can be an running cost.
Page 13
1. Tack out the batteries of remote control. 2. Press the temperature button simultaneously and insert the battery again. 3. Make sure the remote control display shown as Step 2 Enter the Options Setup mode and select your options asscording to the following procedure. Samsung Electronics...
Page 14
’ ’ Ding’ ’ or ’ ’ Diriring’ ’ is heard and the OPERATION ICON( ) lamp of the display me time, then the input of option is completed. (If the deriving sound isn’t heard, try again pressing the ON/OFF button.) Samsung Electronics...
Page 15
Every time you push the button, the display panel reads . . . repeatedly. Push the Mode button to set the display panerl to 1. Every time you push the button, the display panel reads . . . repeatedly. Samsung Electronics...
Page 16
2. If the unit is not working properly or all lamps are continuously □ Option Items Model SEG 1~24 SEG 25~48 SEG 49~72 AR18NSFPEWQ/EU 014005-15625C-27323C-372784 020000-100000-200000-300000 034A4C-113F4A-200000-300001 AR24NSFPEWQ/EU 014005-16629D-27444D-371784 020000-100000-200000-300000 035157-10565C-200000-300001 AR18NSFHBWK/EU 01C005-15625C-27323C-3727A4 020000-100000-200001-300000 034A4C-113F4A-200000-300001 AR24NSFHBWK/EU 01C005-16629D-27444D-3715A4 020000-100000-200001-300000 035157-10565C-200000-300001 Samsung Electronics...
3) Detach COVER-TERMINAL from the PANEL- FRONT.(use + Screw Driver) 4) Loosen connector wire(white) and detach the temperature sensor wire. 5) To detach the FRONT-PANEL the main frame, unfasten 2 screw at the bottom.(use + Screw Driver) NEL,lifting up the bottom. Samsung Electronics...
Page 19
TRAY-DRAIN towards you. CONTROL IN 1) Unfasten the earth screw.(use + Screw Driver) 2) Detach COVER-CONTROL from the CASECONTROL. 3) Detach the temperature sensor. 4) Loosen MOTOR Wire. 5) Take o the CASE-CONTROL from the main frame. Samsung Electronics...
Page 20
Operating Instructions and Installation Parts Procedure Remark 1) Unfasten the screw. 2) Cut the cable tie. 3) Loosen the terminal block wires. Caution: The terminal is locking type. So, when you separate terminals, pull pressing the button. Button Samsung Electronics...
Page 21
7) Loosen the Thermistor wire connector Caution: When you separate the connector, pull pressing the locking button. 8) Loosen the Communication Wire connector and Terminal-Block Fuse connector Caution: When you separate the connector, pull pressing the locking button. Samsung Electronics...
Page 22
1) Unfasten the screw at the right side. (use + Screw Driver) 2) Unfasten the screw at the left side. (use + Screw Driver) 3) Detach the HOLDER PIPE. 4) Take o the EVAPORATOR from the main frame. Samsung Electronics...
Page 23
2) unfasten the 3 points screws in the CASE- CONTROL, and then detach the CASE. (use + Screw Driver) 3) unfasten the screw a little.(use + Screw Driver) 4) Lift up the evaporator slightly and pull the CROSS-FAN to the left side. Samsung Electronics...
Page 28
Parts Procedure Remark Compressor 1) Loosen the fixing nut and detach the Compressor Lead Wire. (Use Monkey Spanner.) 2) Loosen the bolts at the bottom of Compressor like the picture on the right side. (Use Monkey Spanner.) 4-14 Samsung Electronics...
Page 29
4-3. EEPROM DOWNLOAD Maldives 1) Power off Boracay Normal EER (only) 2) Take off the Cabinet : Check the LED off 3) Connect PC-Download Download Connector (10pin) Jig-PBA 4-13...
Page 30
3) Connect PC-Download Jig-PBA Download Connector (10pin) 5) Execute the Universal EEPwriter program 5) CLICK 6) Select COM Port and connect 7) Open the file 8) Start Download 7) CLICK 8) CLICK 4-20...
Page 34
SOLDER-CREAM SOLDER-CREAM ..3 0402-001192 D103 DIODE-RECTIFIER 1 PC ..3 0402-001192 D104 DIODE-RECTIFIER 1 PC ..3 0402-001741 D701 DIODE-RECTIFIER 1 PC ..3 0402-001795 D101 DIODE-RECTIFIER 1 PC ..3 0402-001795 D102 DIODE-RECTIFIER 1 PC ..3 0406-001204 CD81 DIODE-TVS 1 PC Samsung Electronics...
Page 35
1 PC ..3 2007-000138 R809 R-CHIP 1 PC ..3 2007-000140 R538 R-CHIP 1 PC ..3 2007-000140 R545 R-CHIP 1 PC ..3 2007-000140 R815 R-CHIP 1 PC ..3 2007-000140 R901 R-CHIP 1 PC ..3 2007-000141 R814 R-CHIP 1 PC Samsung Electronics...
Page 36
1 PC ..3 2007-007313 R401 R-CHIP 1 PC ..3 2007-007313 R402 R-CHIP 1 PC ..3 2007-007313 R403 R-CHIP 1 PC ..3 2007-007455 R110 R-CHIP 1 PC ..3 2007-009922 R301 R-CHIP 1 PC ..3 2007-009922 R302 R-CHIP 1 PC Samsung Electronics...
Page 37
..3 2402-001145 CE102 C-AL,SMD 1 PC ..3 2802-001211 X501 RESONATOR-CERAMIC 1 PC ..3 DB41-01296A PCB MAIN PCB MAIN 1 PC ..3 DB91-01752A MIC04 ASSY MICOM 1 PC ..4 0903-001864 IC-MICROCONTROLLER 1 PC DC26-00043A TRAN1 TRANS SWITCHING 1 PC Samsung Electronics...
If not, there exists a possibility of re which can be caused by electric heat in the connecting part. : Good Bad : Ring terminal is connected reversely Bad : Not clamped Screw Bad : In the gap between Ring terminal & Screw Bad : Unused Ring Terminal Samsung Electronics...
9-1-1 Indoor Unit Overview For the product componeat images related to each section, see the pages at the front of this manual. 01 Air intake 05 Room temperature sensor 02 Air filter 06 Display 03 Air flow blade (up and down) 07 Power button / Remote control receiver 04 Air flow blade (left and right)
Outdoor Unit 9-1-2 AR18NSFPEWQXEU AR24NSFPEWQXEU AR18NSFHBWKXEU AR24NSFHBWKXEU...
Page 54
Remote Control Overview 01 Set temperature indicator 11 Temperature button 02 Timer option indicator 12 Options button 03 Operation mode indicator 13 Timer button 04 Options indicator 14 Direction button / Selection button 05 Low battery indicator 15 Vertical air swing button 06 Transmit indicator 16 Mode button 07 Fan speed indicator...
Page 55
HEAT mode, and indoor fan and out- Indoor fan and outdoor fan stop operation door fan do not operate intermittently for within 20% intermittently in a HEAT mode. of the total heater operation. Samsung Electronics 10-1...
Page 56
Is the power is normal? Exchange the PBA of no power unit (check the LED Lamp) Exchange the indoor unit PBA. Is the communication error occurred again? Terminate the service. Exchange the outdoor unit PBA. 10-2 Samsung Electronics...
Page 57
Is the connection of power cable supply power and measure the voltage of #1-#2 in and communication cable normal? the connector Exchange the indoor PBA Below 0.5V or Over 4.5V? Micom error or connector check Exchange the indoor PBA Samsung Electronics 10-3...
Page 58
Is the connection of power cable supply power and measure the voltage of #3-#4 and communication cable normal? and #5-#6 in the connector Exchange the indoor PBA Below 0.5V or Over 4.5V? Micom error or connector check Exchange the indoor PBA 10-4 Samsung Electronics...
Page 59
Is the connected louver wire? Does operation start when swing button of the Normal remote control unit pushed? Is the voltage changeable at the pin#2~#5 of CN61, Exchange the PBA CN62, CN63 (louver connector)? Up/Down louver motor is faulty. Samsung Electronics 10-5...
Page 60
Is the voltage of CN72 Exchange the Indoor PBA #3-#5 and #3-#6 with in 1Vdc~15Vdc during the operation? PBA problem or Motor problem Change the PBA first and check the operation Exchange the Fan motor 10-6 Samsung Electronics...
Page 61
Is the connection of power cable supply power and measure the voltage of and communication cable normal? "(#1-#2)” i n the connector Exchange the Outdoor PBA Below 0.5Vdc or Over 4.5Vdc? Micom error or connector check Exchange the Outdoor PBA Samsung Electronics 10-7...
Page 62
Is the connection of power cable p ower and measure the voltage of "(#5-#6)" in the connector and communication cable normal? Exchange the Outdoor PBA Below 0.5Vdc or Over 4.5Vdc? Micom error or connector check Exchange the Outdoor PBA 10-8 Samsung Electronics...
Page 63
Is the connection of power cable supply power and measure the voltage of "(#3-#4) "in the connector and communication cable normal? Exchange the Outdoor PBA Below 0.5Vdc or Over 4.5Vdc? Micom error or connector check Exchange the Outdoor PBA Samsung Electronics 10-9...
Page 64
Restart after power o Is the discharge over temperature Terminate the service sensor error appeared again? Download the EEPROM data Is the discharge over temperature Terminate the service sensor error appeared again? Exchange the Outdoor PBA Exchanged the Compressor 10-10 Samsung Electronics...
Page 65
Is the voltage of "CNP901" #1-#3 over 250Vdc power supply error check Is the voltage of "CNP901" #3-#5 and Exchange the Outdoor PBA #3-#6 with in 1Vdc~15Vdc during the operation? PBA problem or Motor problem rst and check the operation Exchange the Fan motor Samsung Electronics 10-11...
Page 66
Is the connection of compressor wire is normal? Connect the comp wire normally Download the EEPROM data Is the restart error occurred again? Terminate the service Is the compressor body and interphase Exchange the Outdoor PBA resistance insulated? Exchange the compressor 10-12 Samsung Electronics...
Page 67
Is the connection of compressor wire is normal? Connect the comp wire normally (PBA and Compressor) Is the restart error occurred again? Terminate the service Is the compressor body and Exchange the Outdoor PBA interphase resistance insulated? Exchange the compressor Samsung Electronics 10-13...
Page 68
Connect the comp wire normally Is the O.C error occurred again? Terminate the service Is the condition of indoor/outdoor temperature Restart after returning to the normal load normal load? Is the O.C error Terminate the service occurred again? 10-14 Samsung Electronics...
Page 69
Is the position of Correct the sensor position or temperature sensor and sensing exchange the sensor value normal? Is the compressor body and interphase resistance Exchange the Outdoor PBA insulated? Exchange the compressor Samsung Electronics 10-15...
Page 70
Check the power input Normal range(280Vdc~320Vdc) Is the DC_link sensing voltage("R101") is normal in operation mode? Exchange the Outdoor PBA Normal range (0.2Vdc~4.8Vdc) Exchange the Outdoor PBA Is the reactor insulation damaged? Exchange the Reactor 10-16 Samsung Electronics...
Page 71
Start the operation (cooling mode or heating mode) Is the DC_link sensing voltage("B") is normal in operation mode? Exchange the Outdoor PBA Normal range (0.2Vdc~4.8Vdc) Exchange the Outdoor PBA Is the reactor insulation damaged? Exchange the Reactor Samsung Electronics 10-17...
Page 72
Is the the input voltage is nomal? Check the input power in the powercord. Normal range(180Vac ~ 270Vac) Rest Start the operation (cooling mode or heating mode) Is the DC_link voltage ("CE101,CE102,CE103") is normal in operation mode? Check the input power Normal range(280Vdc~320Vdc) 10-18 Samsung Electronics...
Page 73
Is the DC_link sensing Exchange the Outdoor PBA voltage("R105")is normal in operation mode? Normal range (0.2Vdc~4.0Vdc) Exchange the Outdoor PBA Is the reactor insulation damaged? Exchange the Reactor Samsung Electronics 10-19...
Page 74
Is the position of Correct the sensor position or temperature sensor and the sensing exchange the sensor value normal? Is the connection cable for the compressor and power Correct the cable connection terminal normal? Exchange the Outdoor PBA 10-20 Samsung Electronics...
Page 75
3) Is there no short or open around "IC451" ? 2. Troubleshooting procedure Rest Is the PFC shunt and IPM Exchange the Outdoor PBA shunt resistance value correct? Is the current sensor error appeared again? Terminate the service Exchange the Outdoor PBA Samsung Electronics 10-21...
Page 76
4) Is the cover assembly in control-box normal? 2. Troubleshooting procedure Restart after power off. Are there screws in PBA-heatsink? Fastening the screw (4 screws) Check the fan connection Is the fan operation normal? Change the Fan motor Exchange the Outdoor PBA 10-22 Samsung Electronics...
Page 77
Is the Comp Vlimit error occurred again? Terminate the service Is the condition of indoor/outdoor temperature Restart after returning to the normal load normal load? Is the O.C error Terminate the occurred again? service Samsung Electronics 10-23...
Page 78
Is the position of Correct the sensor position or temperature sensor and sensing exchange the sensor value normal? Is the compressor body and interphase resistance Exchange the Outdoor PBA insulated? Exchange the compressor 10-24 Samsung Electronics...
Page 79
2. Troubleshooting procedure MODEL "A" DB92-02866A CN501 DB92-02867A CN202 power o and download EEPROM data (or. Insert the service EEPROM IC) Restart after power o Terminate the service Is the error appeared again? Exchange the Outdoor PBA Samsung Electronics 10-25...
Page 80
* Heating mode * * Cooling mode * Is the outdoor temperature over 40 or Is the outdoor temperature under -7 under -30 ? The temperature condition is too poor to operate. Wait until temperature is changed 10-26 Samsung Electronics...
Page 81
Terminate the service. Check the EEV valve operation. Is the EEV valve connection normal? Connect the EEV valve. Is the EEV valve is operation? Check the sound of EEV valve Change the EEV valve. after power on. Samsung Electronics 10-27...
Page 82
Check the pipe crack. Is the pressure of refrigerant normal? Fill up the refrigerant. Exchange the Indoor PBA Exchange the Outdoor PBA 10-28 Samsung Electronics...
Page 83
Exchange the Main PBA Restart after power o . Is the power normal? Check the power source. Is AC power is normal for SMPS? Exchange the Main PBA CN150 : 220Vac~240Vac Check SMPS wire connection Exchange the PBA Samsung Electronics 10-29...
Page 84
MAIN 12V(CE175) : 11Vdc ~ 13Vdc Is the SMPS is normal? Exchange the SMPS PBA MAIN 18V(CE170) : 17Vdc ~19Vdc Is the SMPS is normal? Exchange the SMPS PBA MAIN 5V(CE174) : 4.5V ~ 5.5Vdc Exchange the PBA Samsung Electronics 10-30...
Page 85
2) Check the battery in remote control 3) All the lights out and check again : Change electronic typed to a rescent light 4) Put the set in operation and check the voltage of display PBA 5) Replace the display PBA 10-31 Samsung Electronics...
Page 86
Is the EEV valve is operation? Change the EEV valve. Check the sound of EEV valve after power on. Check the pipe crack. Is the pressure of refrigerant normal? Fill up the refrigerant. Exchange the Indoor PBA Exchange the Outdoor PBA Samsung Electronics 10-32...
Page 87
- Discharge temperature and the indoor [Execute the troubleshooting] temperature measurements c Check the refrigerant leaks. that the di erence is more than 10 . Check the PCB Relay. - Fill up perfectly refrigerant after re-vacuum. Execute the related trouble- shooting. 10-33 Samsung Electronics...
Page 88
10-2-31 Pre-inspection Notices 1. Check if you pulled out the AC power plug when you eliminate the PCB or front panel 2. Don't hold the PCB side not impose excessive force on it to eliminate the PCB 3. Don’t pull the lead wire but hold the whole housing to connect or disconnect a connector to the PCB 4.
Page 89
10-2-34 Outdoor detailed inspection procedure procedure Inspection Method Cause . Over current Plug out and pull the PCB out of . AC part and pattern short of Indoor the control box 1) Is 1st fuse disconnected? Check the PCB fuse 2) Is indoor PBA faulty? .
Reference Sheet Index for Model Name 10th 11th 12th 13th 14th Project Capacity Sell Feature Series Color Unit Export INVERTER HP 13Year INVERTER CO 14Year 15Year 16Year 17Year BEST RAC RAC Maldive 1ST MODEL Project Color Name Division Component Sinkeolreo code DA White Deco PM Gray...
Note : Please measure the refrigerant pressure after the air conditioner operates on testing cooling mode during more than 10 minutes. Indoor Temp. Variation : 20°C ~ 32°C Outdoor Temp. Variation : -5°C ~ 45°C Low Refrigerant Pressure Distribution AR18NSF**W*XEU AR24NSF**W*XEU Samsung Electronics 12-2...
Page 99
12-5 12-5-1 Opening the panel Tightly grab top of the front panel and pull it down to open. Then slightly lift the panel up. and slide it down. Open the panel and put the Air lter out. Clean the Air lter with a vacuum cleaner or soft brush. If dust is too heavy, rinse it with running water.
Page 104
Within a 3% Deviation from Each Voltage at the Main Terminal of Voltage Imbalance Outdoor Unit Starting Voltage Higher than 80% of the Rated Voltage 12-7-4 WORKING RANGE Applicable models: AR18NSFPEWQNEU AR18NSFHBWKNEU AR24NSFPEWQNEU AR24NSFHBWKNEU Working Range Min(℃) Max(℃) Rated(℃) Working Range Min(℃)