Table of Contents

Advertisement

Quick Links

ACC/ARTM-7221/FC
Installation Guide
6806800E98A
March 2008

Advertisement

Table of Contents
loading

Summary of Contents for Emerson ACC/ARTM-7221/FC

  • Page 1 ACC/ARTM-7221/FC Installation Guide 6806800E98A March 2008...
  • Page 2 Emerson reserves the right to revise this document and to make changes from time to time in the content hereof without obligation of Emerson to notify any person of such revision or changes.
  • Page 3: Table Of Contents

    2.5.2 LEDs..............48 ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 4 Related Documentation ............57 A.1 Emerson Network Power - Embedded Computing Documents ......57 Index .
  • Page 5 Available IPMI Sensors ..........54 ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 6 List of Tables ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 7 Figure 2-23 Location of IPMI Temperature Sensor ........56 ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 8 List of Figures ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 9: About This Manual

    Intelligent Platform Management Controller IPMI Intelligent Platform Management Interface Light Emitting Diode Linear Feet per Minute PICMG PCI Industrial Computer Manufacturers Group PCI Mezzanine Card Read-Only Memory Twisted Pair Ethernet Transmit Data Universal Serial Bus Elektromagnetische Vertraeglichkeit ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 10 File > Exit Notation for selecting a submenu <text> Notation for variables and keys [text] Notation for software buttons to click on the screen and parameter description Repeated item for example node 1, node 2, ..., node 12 ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 11 LED description; renamed RTM name to ACC/ARTM- 7221/FC; added power requirements and critical temperature spots 223454 April 2006 Update for final release 223454 April 2006 Update on installation procedure 6806800E9 March 2008 Update document to Emerson style (logo, copyright, etc.) ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 12 Mail comments to us by filling out the following online form: http://www.emersonnetworkpowerembeddedcomputing.com/ > Contact Us > Online Form In "Area of Interest" select "Technical Documentation". Be sure to include the title, part number, and revision of the manual and tell us how you used it. ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 13: Safety Notes

    The RTM has been tested in a standard Emerson system and found to comply with the limits for a Class A digital device in this system, pursuant to part 15 of the FCC Rules, EN 55022 Class A respectively.
  • Page 14 LED is permanently ON. RTM Damage Installing the RTM with other blades than the PENT/ATCA-7221 damages the RTM. Only install the RTM with the Emerson PENT/ATCA-7221 blade. Operation RTM damage High humidity and condensation on the RTM surface causes short circuits.
  • Page 15 Laser Some variants of the RTM are a Class I laser product. The use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 16 Safety Notes ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 17: Sicherheitshinweise

    Anwendungen in der Telekommunikationsindustrie und im Zusammenhang mit Industriesteuerungen verwendet werden. Installation, Wartung und Betrieb dürfen nur von durch Emerson ausgebildetem oder im Bereich Elektronik oder Elektrotechnik qualifiziertem Personal durchgeführt werden. Die in diesem Handbuch enthaltenen Informationen dienen ausschließlich dazu, das Wissen von Fachpersonal zu ergänzen, können es aber in keinem Fall ersetzen.
  • Page 18 Beschädigung des RTMs Wenn Sie das RTM nicht zusammen mit dem PENT/ATCA-7221 Front Blade installieren, wird das RTM beschädigt. Installieren Sie das RTM deshalb nur zusammen mit dem Emerson PENT/ATCA-7221 Front Blade. Datenverlust Wenn Sie das RTM aus einem eingeschaltetem System herausziehen während die blaue LED auf dem Front Blade noch blinkt, gehen Daten verloren.
  • Page 19 Einige Varianten des Produktes sind Laserprodukte der Klasse I. Um nicht schädlicher Laserstrahlung ausgesetzt zu werden, beachten Sie die folgenden Hinweise: Anpassungen am Produkt, die Bedienung von Steuerelementen sowie die Durchführung von Prozeduren dürfen nur gemäß den Anweisungen in diesem Dokument erfolgen. ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 20 Sicherheitshinweise ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 21: Introduction

    We welcome and appreciate your comments on our documentation. We want to know what you think about our manuals and how we can make them better. Mail comments to: Emerson Network Power - Embedded Computing GmbH Lilienthalstraße 15 85579 Neubiberg Germany Email: reader-comments@mcg.mot.com...
  • Page 22: Features

    Introduction Features Features The ACC/ARTM-7221/FC is a rear transition module (RTM) which provides easy access to I/O signals of the Emerson PENT/ATCA-7221 front blade. The I/O signals are available via the zone 3 connectors. The ACC/ARTM-7221/FC provides the following: System management/IPMI –...
  • Page 23: Standard Compliances

    63 4.3.2. The test consisted of dropping the RTM from 100mm height. As a result of the test, some locating pins were damaged which fix the two alignment blocks that are required by the PICMG 3.0 specification. Due to the damage, the alignment blocks were allowed to rotate slightly. ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 24: Figure 1-1 Declaration Of Conformity

    Introduction Standard Compliances Figure 1-1 Declaration of Conformity ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 25: Mechanical Data

    Weight of RTM 0.7 kg Ordering Information As of the time of writing this guide, the following RTM variant was available. Consult your local sales representative for a more-up-to-date list. Order Number Variant name 121914 ACC/ARTM-7221/FC ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 26 Introduction Ordering Information ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 27: Installation

    Action Plan - Part 1 Start Installation Inspect delivered package items Make sure requirements are met Hard disk to be connected or to be installed? Connect/install hard disk IPMB1 device to be connected? Connect IPMB1 device ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 28 Is slot powered? Switch on system power Switch off slot power Install RTM Install RTM Install RTM Cables to face plate connectors necessary? Connect cables to face plate connectors Switch on slot power Installation finished ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 29: Before You Start

    Before installing the RTM, make sure the requirements described in this section are met. 2.2.2.1 Power Requirements The RTM draws approximately 5W from the front blade it is connected to to. 2.2.2.2 Backplane Requirements For installing the RTM, you need a system without a zone 3 midplane. ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 30: Environmental Requirements

    Temp. Change +/- 0.25ºC/min according to +/- 0.25ºC/min NEBS Standard GR-63- CORE Rel. Humidity 5% to 95% non-condensing 5% to 95% non-condensing according to Emerson- according to Emerson- internal environmental requirements internal environmental requirements ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 31 0.5 mm amplitude 1g 1 mm amplitude 2.0 g 5-20 Hz 20-250 Hz Shock 5 g/11 ms halfsine 15 g/11 ms half sine according to Emerson-internal according to Emerson- environmental requirements internal environmental requirements Free Fall 1,200 mm/all edges and corners To guarantee proper RTM operation, you have to make sure that the temperature at the following location is not exceeded.
  • Page 32: On-Board Connectors

    IPMB1 interface of the ATCA-7221. The following figure shows the location of the IPMB1 connector. Figure 2-4 Location of IPMB1 Connector IPMB1 Connector The following figure shows the pinout of the IPMB1 connector. Figure 2-5 IPMB1 Connector Pinout IPMB1_SDA IPMB1_SCL ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 33: Sata For On-Board Hard Disks

    ACC/ATCA-7221/HDD/SATA for the RTM. For further information refer to the ACC/ATCA-7221/HDD/SATA Installation Guide which can be downloaded from the Emerson literature catalog. Figure 2-6 Location of Serial ATA Connector for On-Board Hard Disks...
  • Page 34: Figure 2-7 Serial Ata For On-Board Hard Disk Connector Pinout

    Installation SATA for On-board Hard Disks The following figure shows the connector pinout. Figure 2-7 Serial ATA for On-Board Hard Disk Connector Pinout SATA0_TX+ SATA0_TX- SATA0_RX- SATA0_RX+ 3.3V 3.3V 3.3V ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 35: Serial Ata For External Hard Disks

    Figure 2-8 Location of Serial ATA Connector for External Hard-Disks SATA Connector for external hard disks The following figure shows the connector pinout. Figure 2-9 Serial ATA for External Hard Disks Connector Pinout SATA_TX_P SATA_TX_M SATA_RX_M SATA_RX_P ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 36: Module Installation

    The RTM can be installed into a powered or nonpowered system and must be installed into a AdvancedTCA system without a zone 3 midplane. RTM Damage Installing the RTM with other blades than the PENT/ATCA-7221 damages the RTM. Only install the RTM with the Emerson PENT/ATCA-7221 blade. 2.4.1 Nonpowered System Damage of Circuits Electrostatic discharge and incorrect RTM installation and removal can damage circuits or shorten their life.
  • Page 37: Powered System

    The blue LED on the front blade starts to flash while the front blade powers down. 3. Wait until the blue LED on the front blade is ON 4. Ensure that the top and the bottom handles of the RTM are in outward position ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 38 7. Insert the front blade from the system's front into the same slot as the RTM 8. Close the handles of the front blade The blue LED on the front blade starts flashing during the power-up procedure. 9. Tighten the two face plate screws on the front blade ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 39 RTM Malfunctioning Incorrect RTM installation and removal can result in RTM malfunctioning. When plugging the RTM in or removing it, do not press on the face plate but use the handles. 6. Remove the RTM from slot ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 40: Face Plate Controls, Indicators And Connectors

    Installation Face Plate Controls, Indicators and Connectors Face Plate Controls, Indicators and Connectors The following figure shows the face plate of the RTM. Figure 2-10 Face Plate ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 41: Connectors

    COM or connecting a serial device to a RJ-45 connector labeled as E1/T1 may damage the telephone or the RTM. Therefore, only connect E1/T1 networks to RJ-45 connectors labeled as E1/T1 ports and only connect serial devices to RJ-45 connectors labeled as COM. ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 42: Fiber Channel

    PS/2 keyboard and mouse simultaneously. The following connector pinout gives information on which signal is assigned to which pin. Figure 2-14 Keyboard/Mouse Connector Pinout Keyboard data Mouse data VP5_KBD Keyboard clock Mouse clock ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 43: E1/T1

    The following connector pinout gives information on which signal is assigned to which pin. The "x" stands for the number of the interface. Figure 2-15 E1/T1 Connector Pinout RX+_x RX-_x n.c. TX+_x TX-_x n.c. n.c. n.c. ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 44: Leds

    Installation LEDs 2.5.2 LEDs The following figure highlights the LEDs available at the RTM's face plate. . Figure 2-16 Face Plate LEDs Face Pate LEDs ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 45 OFF: RTM is active and cannot be removed The status of all LEDs can be determined via the PICMG 3.0 command "Get FRU LED State". The status of the LEDs can be changed via the PICMG 3.0 command "Set FRU LED State". ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 46: Reset Key

    The RTM's MMC and the front blade's IPMC are not reset via this key. Zone 3 Connectors The RTM provides two zone 3 connectors: P30 and P31. They provide interfaces to: Serial (RS-232) Serial ATA Fiber channels Keyboard/Mouse IPMI ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 47: Figure 2-18 Location Of Zone 3 Connectors P30 And P31

    RS232_1_DSR RS232_1_RI RS232_1_DCD RS232_1_DTR n.c. n.c. n.c. n.c. USB1_P USB1_M USB0_P USB0_M n.c. n.c. n.c. n.c. FC0_RX_P FC0_RX_M FC0_TX_P FC0_TX_M SATA0_RX_P SATA0_RX_M SATA0_TX_P SATA0_TX_M n.c. n.c. n.c. n.c. V3P3_IPMI n.c. IPMB1_SCL IPMB1_SDA V3P3_RTM V3P3_RTM VP12_RTM VP12_RTM ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 48: Figure 2-20 P30 Connector Pinout, Rows E-H

    PMC1_IO_37 PMC1_IO_39 PMC1_IO_34 PMC1_IO_36 PMC1_IO_45 PMC1_IO_47 PMC1_IO_42 PMC1_IO_44 n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. n.c. V3P3_RTM n.c. VP12_RTM VP5_RTM ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 49: Devices Connected To Rtm's Mezzanine Management Controller

    Intelligent Platform Management Standard V1.5 Rev. 1.1. It is connected to the front blade's IPMC via IPMB1. Emerson offers a Monta Vista Linux Carrier Edition 3.1 (MVL CGE 3.1) driver for the IPMC of the front blade and the MMC of the RTM.
  • Page 50: Figure 2-23 Location Of Ipmi Temperature Sensor

    Location of IPMI sensor ARTM-7221 Temp. For further details about IPMI sensors as well as supported IPMI commands, refer to the ACC/ARTM-7221/FC: Control via IPMI Programmer's Guide which can be downloaded from the Emerson literature catalog. ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 51: Related Documentation

    Documents The Emerson Network Power - Embedded Computing publications listed below are referenced in this manual. You can obtain electronic copies of Emerson Network Power - Embedded Computing publications by contacting your local Emerson sales office. For documentation of final released (GA) products, you can also visit the following website: http://www.emersonnetworkpowerembeddedcomputing.com...
  • Page 52 Related Documentation Emerson Network Power - Embedded Computing Documents ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 53: Index

    For on-board hard disk LEDs Standard compliances Reset key Serial interface connector USB connector Temperatures Critical hot spots Non-operating I2C address of IDROM Operating IDROM I2C address Installation Into nonpowered systems Zone 3 connectors Into powered systems ACC/ARTM-7221/FC Installation Guide (6806800E98A)
  • Page 54 ACC/ARTM-7221/FC Installation Guide (6806800E98A)

Table of Contents