System Alarm Output - NEC Electra Elite IPK II Programming Manual

Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Document Revision 1
Level:
IN
Description
Use Program 90-12 : System Alarm Output to set the options for the alarm report.
This program has 6 separate menu options. Define the output port to be used as the
output for system alarm report and set the system alarm options. The system can
have up to 50 reports.
Input Data
Item
No.
01
02
03
04
05
06
Feature Cross Reference
None
2 - 552
Program 90 : Maintenance Program
Output Port Type
Indicate the type of connection used for the System
Alarms. The baud rate for the COM port should be set in
Program 10-21-02.
Destination Extension Number
If the output port type (item 1) is set to CTA, enter the
extension number with the CTA connection.
Output All Alarm Reports
Printout New Alarm Reports
Clear All Alarm Reports
Output Mode
Conditions
None

90-12 : System Alarm Output

Item
Program 90 : Maintenance Program
Electra Elite IPK II
Input Data
0 = No Setting
1 = COM port (CPUII)
2 = USB port (CPUII)
3 = -- Reserve --
4 = CTA/CTU
Extension Number
(Up to 8 digits)
Print All? (Yes = 1)
Print New? (Yes = 1)
All Clear? (Yes = 1)
0 = Manual
1 = Auto
Default
0
No
Setting
-
-
-
0