NEC Express5800 User Manual page 36

Hide thumbs Also See for Express5800:
Table of Contents

Advertisement

2-12 General Description
On-screen message
Battery Alm XX
Proc1 Vccp AlmXX
Proc2 Vccp AlmXX
BB FSBvtt Alm XX
BB DIMMvtt AlmXX
BB +1.2v Alm XX
BB +1.5v Alm XX
BB +1.8v Alm XX
BB +3.3v Alm XX
BB +5v Alm XX
BB +1.2vs Alm XX
BB +1.5vs Alm XX
BB +1.25vs AlmXX
BB +3.3vs Alm XX
BB +5vs Alm XX
BB +12vs Alm XX
Virtual LCD indications when STATUS lamp is flashing in amber
On-screen message
Mem Reconfigured
Mem Err Disable
CPU Reconfigured
HDD 0 Fault
HDD 1 Fault
E-Keying Error
Location Error
Description
A battery voltage alarm was
detected.
XX=09: Upper limit alarm
XX=02: Lower limit alarm
A voltage alarm was detected.
XX=09: Upper limit alarm
XX=02: Lower limit alarm
Description
The memory is degraded.
Correctable memory error frequently
occurs.
The CPU is degraded.
An error was detected in hard disk
drive in slot 0.
An error was detected in hard disk
drive in slot 1.
In the Blade Enclosure, combination
of installation locations of CPU
blade, mezzanine card, and switch
module is not correct. Thus, an
unconformity of interface signal was
detected and the CPU blade failed to
power on.
In the Blade Enclosure, the
installation location of CPU blade is
incorrect, or the installation locations
of the fan and CPU blade are
incorrect. Thus, the CPU blade failed
to power on.
Action
1. Check installation status of the
battery.
2. Replace the battery.
Replace the CPU blade.
Action
1. Check installation status of
DIMM.
2. Replace the DIMM.
1. Check installation status of CPU.
2. Replace the CPU.
Check hard disk drive.
Refer to the User's Guide of Blade
Enclosure for correct installation
locations.
Refer to the User's Guide of Blade
Enclosure to check if the CPU blade
is installed in correct location.
Check the installation locations of
the fan and CPU blade.

Advertisement

Table of Contents
loading

Table of Contents