For Service Engineer
Service Information
(6) When the teaching operation is completed normally, make a note of the values in the
"Before" and "After" sections.
(7) Press the [Save] button to save the data.
1.4.5.10.

Nozzle Inclination Offset Teaching

Under each of the following conditions, this teaching is required.
 It affects the placement accuracy directly.
 The in-house adjustment is to be performed.
 The offset teaching is to be performed when the machine is delivered.
 The head has been changed.
 The PEC recognition camera is to be changed.
 The component recognition camera is to be changed.
 X-axis or Y-axis linear scale and scale head are to be changed.
Required Jig and Tool
QFP Glass Jig
: JG-0188 1 unit
Vacuum Nozzle : HA19C 1 unit
Purpose (Nozzle Inclination Offset)
The deviation of the set nozzle height at the component recognition operation from the
actual nozzle height is adjusted using the offset adjustment operation.
This offset is available when the component with the 0603 size or smaller, is placed.
Fig. A36