4.8.1 Domestic hot water tanks

A domestic hot water tank is used for the production and intermediate storage of domestic hot
water (DHW). By integrating a solar system, solar heat can also be stored in this intermediate
storage and used in addition to the heat from the Aquarea heat pump. An electric booster heater
(tank heater) additionally ensures maximum comfort, even at very low outside temperatures, and
can also be used for sterilisation.
Panasonic offers various DHW tank models in different sizes for easy domestic hot water
production for different requirements.
72
1
2
3
4
5
6
7
2-way valve
3-way valve
Electric tank
heater
Connection
Function
2-way valve
Output for actuation of the 2-way valve (e.g.
for floor heating, cooling)
3-way valve
Output for actuation of the 3-way valve (e.g.
for heating, domestic hot water tank)
Electric tank heater
Output for on/off switch of the electric tank
heater
Room thermostat
Input for room thermostat signals
Overload protection
Input for overload protection of the domestic
for domestic hot water
hot water tank
tank
Temperature sensor of
Input for temperature sensor of the domestic
the hot water tank
hot water tank
External control signal
Input for the external control signal
Solar system 3-way
Output for actuation of the solar system 3-way
valve
valve
Solar system pump
Input of the ON signal of solar system pump 2
(230 V AC)
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
8
9 10 11 12
13 14 15 16 17 18
Room
Temperature
thermostat
sensor for hot
water tank
Overload
External control
protection for hot
water tank
Condition
The maximum power output of the electric
tank heater should be maximum 3 kW.
The terminals 13/14 must be used if
overload protection is not used for the hot
water tank.
These two terminals are bridged at the
time of dispatch. Connection: 1-pin (min.
3 mm contact distance)
Use optional solar connection PCB
CZ-NS1P, CZ-NS2P or CZ-NS3P.
19 20 21
22 23
Solar system
Solar system
3-way valve
pump
signal
Cable cross
section
3 × min.
0.5 mm²
3 × min.
0.5 mm²
3 × min.
1.5 mm²
4, or 3 × min.
0.5 mm²
2 × min.
0.5 mm²
2 × min.
0.5 mm²
2 × min.
0.5 mm²
3 × min.
0.5 mm²
2 × min.
0.5 mm²