Risk of explosion due to static charging
If you clean the motor, plastic components may become statically charged and ignite a
potentially explosive atmosphere. An explosion can occur. This can result in death, serious
injury or material damage.
• When cleaning ensure that there is absolutely no explosive atmosphere present.
• Clean the plastic parts and components so that absolutely no static charging occurs
• Do not use compressed air for cleaning.
8.1.1

Safety note for ventilation

8.1.1.1
Forced ventilation (optional): Cooling method IC 416 in accordance with
EN / IEC 60034-6
Explosion hazard if the temperature class is exceeded
If a force-ventilated machine is operated without a separately driven fan, the temperature
class or the maximum surface temperature of the machine can be exceeded.
In an explosive atmosphere, there is a risk of an explosion. This can result in death, serious
injury or material damage.
• Install an interlock circuit that prevents the machine from being switched on if the
separately driven fan is not switched on/is not operational.
• Do not commission the machine without a separately driven fan.
Risk of injury when touching the fan
There is a risk of injury at machines equipped with a fan cover (e.g. on machines in the
textile industry), as the fan is not completely touch protected.
• Do not touch the rotating fan.
• Do not put your fingers into the larger air discharge openings.
• Prevent manual intervention by using suitable measures, e.g. appropriate housings or a
1MB..5/6 shaft height 71 ... 355
Operating Instructions, 10/2021, A5E41926185A
CAUTION
protective grating.