Siemens SIMATIC NET RUGGEDCOM RS8000A Installation Manual

Siemens SIMATIC NET RUGGEDCOM RS8000A Installation Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RS8000A:

Advertisement

Quick Links

Edition
12/2021
Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM RS8000A
https://www.siemens.com/ruggedcom

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM RS8000A

  • Page 1 Edition 12/2021 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RS8000A https://www.siemens.com/ruggedcom...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RS8000A Communication Ports Technical Specifications Installation Manual Certification 12/2021 C79000-G8976-1021-06...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................vi Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 4 Decommissioning and Disposal ................4 Cabling Recommendations ..................
  • Page 5 Table of Contents Failsafe Relay Specifications ................21 Copper Ethernet Port Specifications ..............21 Fiber Optic Ethernet Port Specifications ............... 22 Operating Environment ..................22 Mechanical Specifications ..................23 Dimension Drawings ................... 23 Certification ......................... 27 Approvals ......................27 6.1.1 CSA ........................
  • Page 6: Preface

    SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document. The glossary is available online via Siemens Industry Online Support (SIOS) at: https://support.industry.siemens.com/cs/ww/en/view/50305045 Accessing Documentation The latest user documentation for RUGGEDCOM RS8000A is available online at https://support.industry.siemens.com.
  • Page 7: Warranty

    Preface Warranty Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 8: Contacting Siemens

    Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit https://w3.siemens.com/aspa_app/?lang=en. Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RS8000A Installation Manual, 12/2021, C79000-G8976-1021-06...
  • Page 10: Introduction

    Introduction The RUGGEDCOM RUGGEDCOM RS8000A provides substation hardened, fully managed, Ethernet switches specifically designed to operate reliably in electrically and environmentally harsh environments. The RUGGEDCOM RS8000A model provides IEEE 1613 Class 2 error-free communications performance under EMI stress. An operating temperature range of -40 to 85 °C (-40 to 185 °F) allows the RUGGEDCOM RS8000A to be placed in almost any location.
  • Page 11: Description

    Introduction 1.2 Description • -40 to 85 °C (-40 to 185 °F) operating temperature (no fans) • Failsafe Output Relay: For critical failure or error alarming • Conformal coated printed circuit boards (optional) Cyber Security Features • Multi-level user passwords • SSH/SSL (128-bit encryption) •...
  • Page 12 Introduction 1.2 Description POWER LED RESET Button Communication Ports Port Status Indicator LEDS RS232 Serial Console Port (DB9) Figure 1.1 Front and Rear Panels POWER LED Illuminates when power is being supplied to the device. Color Description Green Device ready No power RESET Button Shuts down and restarts the device.
  • Page 13: Required Tools And Materials

    Introduction 1.3 Required Tools and Materials RS232 Serial Console Port The serial console port is for interfacing directly with the device and accessing initial management functions. For information about connecting to the device via the serial console port, refer to "Connecting to the Device (Page 17)".
  • Page 14: Supported Fiber Optic Cables

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 15 Introduction 1.5.1 Supported Fiber Optic Cables RUGGEDCOM RS8000A Installation Manual, 12/2021, C79000-G8976-1021-06...
  • Page 16: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 17: General Procedure

    Installing the Device 2.1 General Procedure NOTICE This product should be installed in a restricted access location where access can only be gained by authorized personnel who have been informed of the restrictions and any precautions that must be taken. Access must only be possible through the use of a tool, lock and key, or other means of security, and controlled by the authority responsible for the location.
  • Page 18: Mounting The Device On A Din Rail

    Installing the Device 2.2.1 Mounting the Device on a DIN Rail 2.2.1 Mounting the Device on a DIN Rail The RUGGEDCOM RS8000A can be ordered with a panel/DIN rail adapter preinstalled on the back of the chassis. Use the adapter to mount the device to a standard 35 mm (1.4 in)IEC/EN 60715 or TS35 DIN rail.
  • Page 19: Mounting The Device To A Rack

    Installing the Device 2.2.2 Mounting the Device to a Rack Removing the Device To remove the device from a DIN rail, do the following: Insert a flathead screwdriver into the slot of the sliding release and move it down. DIN Rail DIN Rail Adapter Figure 2.2 Removing the Device from a DIN Rail...
  • Page 20 Installing the Device 2.2.2 Mounting the Device to a Rack Insert the device into rack mount adapter and use the screws to secure it. Note The device can be installed with the communication ports facing the front or rear of the rack, depending on the desired orientation. Rack Mount Adapter Screw Figure 2.3...
  • Page 21: Mounting The Device To A Panel

    Installing the Device 2.2.3 Mounting the Device to a Panel 2.2.3 Mounting the Device to a Panel To mount the device to a panel, do the following: Place the device against the panel and align the adapters with the mounting holes. Screw Panel/DIN Rail Adaptor Figure 2.4...
  • Page 22: Connecting Power

    Installing the Device 2.4 Connecting Power more information, refer to the "RUGGEDCOM RS8000A Configuration Manual" for the RUGGEDCOM RS8000A. The following shows the proper relay connections. Normally Closed Common Normally Open Figure 2.5 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RS8000A supports a single integrated high AC/DC or low DC power supply IMPORTANT •...
  • Page 23: Connecting Ac Power

    Installing the Device 2.4.1 Connecting AC Power 2.4.1 Connecting AC Power To connect a high AC power supply to the device, do the following: NOTICE Electrical hazard – risk of damage to equipment Before testing the dielectric strength (HIPOT) in the field, remove the braided ground cable connected to the surge ground terminal and chassis ground.
  • Page 24: Connecting Dc Power

    Installing the Device 2.4.2 Connecting DC Power Using a #6 ring tongue and #6-32 screw, secure the ground terminal on the power source to the chassis ground terminal on the device. Make sure the lug is tightened to 1.7 N·m (15 lbf·in). Stainless Steel Stud #6-32 Screw #6 Ring Tongue...
  • Page 25 Installing the Device 2.4.2 Connecting DC Power Connect the positive wire from the power source to the positive/hot (+/L) terminal on the terminal block. Positive/Hot (+/L) Terminal Negative/Neutral (-/N) Terminal Surge Ground Terminal Braided Ground Cable Figure 2.8 Terminal Block Wiring Connect the negative wire from the power source to the negative/neutral (-/N) on the terminal block.
  • Page 26: Device Management

    Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM ROS console and Web interfaces on the device. For more detailed instructions, refer to the "RUGGEDCOM RS8000A Configuration Manual"...
  • Page 27: Configuring The Device

    Device Management 3.2 Configuring the Device Configuring the Device Once the device is installed and connected to the network, it must be configured. All configuration management is done via the RUGGEDCOM ROS interface. For more information about configuring the device, refer to the "RUGGEDCOM RS8000A Configuration Manual"...
  • Page 28: Communication Ports

    Communication Ports The RUGGEDCOM RS8000A can be equipped with various types of communication ports to enhance its abilities and performance. To determine which ports are equipped on the device, refer to the factory data file available through RUGGEDCOM ROS. For more information on how to access the factory data file, refer to the "RUGGEDCOM RS8000A Configuration Manual"...
  • Page 29: Fiber Optic Ethernet Ports

    Communication Ports 4.2 Fiber Optic Ethernet Ports The following is the pin-out for the RJ45 male connector:   Name Description Receive Data+ Receive Data- Transmit Data+ Reserved (Do Not Connect) Figure 4.2 RJ45 Ethernet Port Pin Reserved (Do Not Connect) Configuration Transmit Data- Reserved (Do Not Connect) Reserved (Do Not Connect) Case...
  • Page 30: Technical Specifications

    Technical Specifications This chapter provides important technical specifications related to the device. Power Supply Specifications Note When determining cable lengths, make sure the nominal input voltage for the power supply is provided at the power source. Input Range Power Internal Fuse Maximum Power Supply Type Rating...
  • Page 31: Fiber Optic Ethernet Port Specifications

    Technical Specifications 5.4 Fiber Optic Ethernet Port Specifications Cable Type > CAT-5 Wiring Standard TIA/EIA T568A/B Maximum Distance 100 m (328 ft) Isolation 1.5 kV Auto-negotiating. Shielded or unshielded. Auto-crossover and auto-polarity. Typical distance. Dependent on the number of connectors and splices. RMS 1 minute.
  • Page 32: Mechanical Specifications

    Technical Specifications 5.6 Mechanical Specifications Maximum Altitude 2000 m (6562 ft) Ambient Temperature as measured from a 30 cm radius surrounding the center of the enclosure. Non-condensing Mechanical Specifications Weight 2.25 kg (5 lbs) Ingress Protection IP30 Enclosure 18 AWG Galvanized Steel Dimension Drawings Note All dimensions are in millimeters, unless otherwise stated.
  • Page 33 Technical Specifications 5.7 Dimension Drawings 248.9 Figure 5.1 Overall Dimensions 479.4 464.5 Figure 5.2 Rack Mount Dimensions RUGGEDCOM RS8000A Installation Manual, 12/2021, C79000-G8976-1021-06...
  • Page 34 Technical Specifications 5.7 Dimension Drawings 274.3 264.2 Figure 5.3 Panel and Din Rail Mount Dimensions RUGGEDCOM RS8000A Installation Manual, 12/2021, C79000-G8976-1021-06...
  • Page 35 Technical Specifications 5.7 Dimension Drawings RUGGEDCOM RS8000A Installation Manual, 12/2021, C79000-G8976-1021-06...
  • Page 36: Certification

    6.1.2 European Union (EU) This device is declared by Siemens Canada Ltd. to comply with essential requirements and other relevant provisions of the following EU directives: EN 62368-1 • Information Technology Equipment – Safety – Part 1: General Requirements •...
  • Page 37: Fcc

    The device is marked with the CE symbol and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd.. For contact information, refer to "Contacting Siemens (Page vii)".
  • Page 38: Rohs

    Certification 6.1.5 RoHS 6.1.5 RoHS This device is declared by Siemens Canada Ltd. to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: • China RoHS 2...
  • Page 39 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels Voltage Dips and Interrupts DC Power 30% for 0.1 s, 60% for   61000-4-29 ports 0.1 s, 100% for 0.05 s AC Power 30% for 1 period,   ports 60% for 50 periods 100% for 5 periods,...
  • Page 40 Certification 6.2 EMC and Environmental Type Tests IEEE Test IEEE 1613 Description Test Levels Clause AC Power ports ±4 kV Earth ground ports ±4 kV Oscillatory Signal ports 2.5 kV common mode @ 1MHz DC Power ports 2.5 kV common and differential mode @ 1MHz AC Power ports 2.5 kV common and...
  • Page 41 Certification 6.2 EMC and Environmental Type Tests RUGGEDCOM RS8000A Installation Manual, 12/2021, C79000-G8976-1021-06...
  • Page 42 For more information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens Canada Ltd. Digital Industries Process Automation 300 Applewood Crescent Concord, Ontario, L4K 4E5 Canada © 2021 Siemens Canada Ltd. Subject to change...

This manual is also suitable for:

Ruggedcom rs8000a

Table of Contents