4 Installation

Installation
4
This chapter shows the necessary steps to put the example into operation with the
code from the download and the hardware list.
The installation guidelines for LOGO!, SINAMICS V20 and S7-1200 always have
Note
to be observed.
Before installing the SINAMICS V20 and putting it into operation, please read all
!
the safety instructions and warnings in its operation instructions and observe the
warning signs in the device. Please make sure that the warning sign remains
readable and is not removed.
Warning
4.1

Set-up plan

Figure 4-1
The set-up plan shows the wiring of the components needed to use the functions of
the LOGO! Set 23.
L1
L2
L3
N
DC24V+
DC24V-
PE
11
Standard PC
STEP 7 (TIA Portal)
A LOGO! Power 1.3A (1) ensures the 24V power supply for the devices.
The automation solution uses a LOGO! logic module (2) with relay outputs and an
integrated clock function
A LOGO! TD (9) is connected to the LOGO! logic module for displaying messages.
The LOGO! AM2 AQ* (3) is used as an expansion module with two analog outputs
One analog output is connected to the SINAMICS V20 frequency converter* (5).
The motor* (6) is connected to the SINAMICS V20 frequency converter.
Set23_RegSim
Entry ID: 23753479,
V2.3.S,
Circuit breaker
I8
I1
7
9
10
02/2014
3
1
2
NH-fuse set
8
5
M
Min
Max
6