 Setting the automatic recognition of the inverter and FR Configurator2
(Ethernet connection)
• To connect the inverter and FR Configurator2 via Ethernet, refer to the following table to check the settings of the relay
device and parameters.
Model
Through
Not connected
FR-A800-E
Programmable
FR-F800-E
controller
GOT to
programmable
controller
Not connected
FR-A800-E-
Programmable
R2R
controller
GOT to
programmable
controller
Not used
FR-E800-
Programmable
(SC)E
controller
GOT to
programmable
controller
74
2. PROJECT CREATION
2.1 Project file operation
Pr.
1427
1428
1429
1442 to 1448
1427
1428
1429
1442 to 1448
1427
1428
1429
*1
1442 to 1448
1076
1077
1078
1442 to 1448
1076
1077
1078
1442 to 1448
1076
1077
1078
*1
1442 to 1448
1427
1428
1429
1430
1442 to 1448
1427
1428
1429
1430
1442 to 1448
1427
1428
1429
1430
*1
1442 to 1448
Name
Ethernet function selection 1
Ethernet function selection 2
Ethernet function selection 3
IP filter address (Ethernet)
Ethernet function selection 1
Ethernet function selection 2
Ethernet function selection 3
IP filter address (Ethernet)
Ethernet function selection 1
Ethernet function selection 2
Ethernet function selection 3
IP filter address (Ethernet)
Ethernet function selection 1
Ethernet function selection 2
Ethernet function selection 3
IP filter address (Ethernet)
Ethernet function selection 1
Ethernet function selection 2
Ethernet function selection 3
IP filter address (Ethernet)
Ethernet function selection 1
Ethernet function selection 2
Ethernet function selection 3
IP filter address (Ethernet)
Ethernet function selection 1
Ethernet function selection 2
Ethernet function selection 3
Ethernet function selection 4
IP filter address (Ethernet)
Ethernet function selection 1
Ethernet function selection 2
Ethernet function selection 3
Ethernet function selection 4
IP filter address (Ethernet)
Ethernet function selection 1
Ethernet function selection 2
Ethernet function selection 3
Ethernet function selection 4
IP filter address (Ethernet)
Setting
Set a combination of "5001" (or "5002") and
"45237" in any two of the parameters.
Set the IP address to within the IP address
range of the personal computer.
Set "5001" in any of the parameters.
Set the IP address to within the IP address
range of the Ethernet module.
Set "5001" in any of the parameters.
Set the IP address to within the IP address
range of the Ethernet module.
Set a combination of "5001" (or "5002") and
"45237" in any two of the parameters.
Set the IP address to within the IP address
range of the personal computer.
Set "5001" in any of the parameters.
Set the IP address to within the IP address
range of the Ethernet module.
Set "5001" in any of the parameters.
Set the IP address to within the IP address
range of the Ethernet module.
Set a combination of "5001" (or "5002") and
"45237" in any two of the parameters.
Set the IP address to within the IP address
range of the personal computer.
Set "5001" in any of the parameters.
Set the IP address to within the IP address
range of the Ethernet module.
Set "5001" in any of the parameters.
Set the IP address to within the IP address
range of the Ethernet module.