Advanced Settings Guide

5 Action Codes

5.1 Humidity Calibration (HC)

Ability to adjust humidity readings after extended product use.
 Options: -5% to 5%
 Default: 0%
1.
Main Menu
2.
Advanced Settings
3.
Installer Access
4.
Enter professional access code "1886"
5.
Enter action code "HC"
6.
Use the Up and Down keys to select humidity calibration
Figure 59

5.2 Relative Humidity Hysteresis (HSD)

Ability to adjust the set point diff erential (hysteresis) for the humidity control.
 Options: 3% to 5%
 Default: 5%
1.
Main Menu
2.
Advanced Settings
3.
Installer Access
4.
Enter professional access code "1886"
5.
Enter action code "HSD"
6.
Use the Up and Down keys to select relative humidity hysteresis
Figure 60
2 4 |

5.3 Initial Setup (IS)

Ability to access the initial setup process typically only initiated the fi rst time a new
unit is powered on, or after a factory reset.
1.
Main Menu
2.
Advanced Settings
3.
Installer Access
4.
Enter professional access code "1886"
5.
Enter action code "IS"
Figure 61

5.4 Sensor Calibration (SC)

Ability to adjust temperature readings after extended use.
 Options: -10.0 to 10.0
 Default: 0.0
1.
Main Menu
2.
Advanced Settings
3.
Installer Access
4.
Enter professional access code "1886"
5.
Enter action code "SC"
6.
Use the Up and Down keys to select sensor calibration
Figure 62